background image

 

 

User’s manual 

- 3 - 

FUM – 2410/15/20CBP 

 

 

 

 

 

 

 

 

 

 

 

 

10. Power switch  

To turn on and off AC power to charger. 

11. Inlet AC socket wirh fuse holder 

B.  Battery type selection 

AGM/GEL 

: Sealed type (VRLA), AGM-GEL, maintenance free, automotive or deep cycle lead acid batteries. 

Wet 

: Flooded type lead acid batteries (to which water can be added) automotive or deep cycle. 

Calcium-Calcium  : Sealed type (VRLA) lead acid batteries with calcium content automotive or deep cycle. 

B1. Float voltage selection 

These fine tuned selections of float voltages enable the best voltage level for maximum battery life. Choose 13.8V when in doubt 
or in power supply mode. 

Follow the markings on deep cycle batteries of the standby float voltage. 

B2. Recommended battery capacity 

The  following  minimum  Ah  capacities  are  a  generalized  suggestion,  some  batteries  can  take  higher  charge  current,  check  with 
battery manufacturers for charging batteries with smaller capacity. 

Charger model 

FUM – 2415CBP, 15A  FUM – 2420CBP, 20A  FUM – 2425CBP, 25A 

Battery capacity 

50 Ah ~ 150 Ah 

70 Ah ~ 200 Ah 

80 Ah ~ 250 Ah 

C.  Battery charger installation and connection 

Observe the warnings & safety precautions before rushing to install and operate the charger. 

Check battery condition, fill up cells for wet battery, clean battery poles. 

Secure the battery charger in a well ventilated place, make sure the mounting surface is flat and without soft covering material or 
loose paper sheet. The air intake is at the bottom and air outlet at the back. Make sure both intake and outlet are not blocked. 

Never place charger on top of battery. 

Plug in the AC mains and turn on power switch, the charger ON LED and the float LED should be on green indicating charger is 
in good order for charging lead acid battery. 

Before  connecting  or  disconnecting  the  charging  cable,  turn  off  the  power  switch  and  unplug  AC  cord  from  the  mains.  First 
connect the red cable to po terminal of charger and the battery po pole. Then connect the black cable to the negative 
– terminal and the negative – pole of the battery. 

Make sure all the connections are secured and well tighten up, double check on the correct polarity. 

Double check again for correct selection of slide switch 1 at charger mode, switch 2 for battery type and switch 3 for float voltage 
setting value. 

Fig.2

Содержание FUM-2410CBP

Страница 1: ...f the charger there is no user serviceable parts inside Do not charge the battery on boats Remove the battery and charge on shore Never attempt to charge a frozen battery Never attempt to charge a damaged battery Wear protective goggles and turn your face away when connecting or disconnecting the battery Never place the charger on top of a battery Never smoke use an open flame or create sparks nea...

Страница 2: ... See section G 2 Battery type selection Slide switch to set charger for AGM gel wet and calcium calcium type battery 3 Float voltage selection Slide switch to set float charge voltage to 26 4 27 0V 27 6V 4 Charge status LED display Charger ON LED Green 3 stage charger mode Red Power supply mode BULK LED Red Bulk charging with constant max current ABSORPTION LED Orange Absorption charging with pres...

Страница 3: ... Ah C Battery charger installation and connection Observe the warnings safety precautions before rushing to install and operate the charger Check battery condition fill up cells for wet battery clean battery poles Secure the battery charger in a well ventilated place make sure the mounting surface is flat and without soft covering material or loose paper sheet The air intake is at the bottom and a...

Страница 4: ...dependently by user according to the type of battery such that battery can be connected permanently to the charger when it is not in use E Manual equalization charging for wet type battery only Wet lead acid battery requires periodic high voltage charging about 10 overcharge absorption voltage to balance the voltage of each cell reverse the high concentration of electrolyte at the bottom and clear...

Страница 5: ... voltage However a 2 stage charger cannot completely charge the battery when the charger switches from bulk mode to float mode After switching to float mode the battery will in most cases be about 80 recharged The battery receives the remaining recharge while in float mode over several days It is highly recommended to switch back to the 3 stage charger mode periodically when the external load is d...

Страница 6: ...perature control function never plug in the charger during charging I Cable size selection Wire size AWG Area mm Maximum one way distancie for 2 voltage loss 24V 15A Maximum one way distancie for 2 voltage loss 24V 20A Maximum one way distancie for 2 voltage loss 24V 25A 10 5 26 4 65 m 15 3 feet 3 50 m 11 5 feet 2 80 m 9 2 feet 8 8 37 7 31 m 24 feet 5 48 m 18 feet 4 39 m 14 4 feet 6 13 3 11 58 m 3...

Страница 7: ...on even after 20 hours charging time Absorption light remains on all the time Wrong battery type selection eg charge gel battery with Calcium Calcium or wet type selection Check charged battery label and change battery type selection to correct setting Total battery capacity is too high for dual charging Check battery capacity or charge battery separately Battery temperature too high Use temperatu...

Страница 8: ...ll load 100 230VAC 5 6 2 4A 7 4 3 2A 9 3 3 9A Protection Overload 90 110 rated output current or 50 rated output current soft charge Protection type constant current limiting recovers automatically after fault condition is removed Short circuit Recovers automatically after fault condition is removed Reverse polarity Car blade fuse Over temperature Protecction type shut down OVP output over voltage...

Отзывы: