B.  Battery Type Selection

AGM/GEL

: Sealed type (VRLA) , AGM-GEL , Maintenance Free , Automotive or Deep Cycle lead acid batteries

WET

: Flooded Type lead acid batteries (to which water can be added) Automotive or Deep Cycle 

Calcium-Calcium : Sealed type (VRLA) Lead Acid batteries with Calcium content Automotive or Deep Cycle 

B1. FLOAT VOLTAGE SELECTION

These fine tuned selections of float voltages enable the best voltage level for maximum battery life. Choose 27.6V when in doubt
or in Power Supply Mode.
Follow the markings on Deep Cycle batteries of the Standby float voltage.

B2.   Recommended  Battery Capacity 

The following minimum AH capacities are  a generalized suggestion, some batteries can take higher charge current, check with
battery manufacturers for charging batteries with smaller capacity. 

Charger Model

                         FUM

-2

4

05 , 5A

                       FUM

-2

4

07 , 7.5A

                    FUM

-2

4

10 , 10A 

Battery Capacity

20 AH - 50 AH 

30 AH - 80 AH

40 AH - 100 AH 

C. Battery Charger Installation and Connection

Observe the warnings & safety precautions before rushing to install and operate the charger.
Check battery condition, fill up cells for wet battery, clean battery poles.
Secure the battery charger in a well ventilated place, make sure the mounting surface is flat and without soft covering material or
loose paper sheet. The air intake is at the bottom and air outlet at the back. Make sure both intake and outlet are not blocked.
Never place charger on top of battery.
Plug in the AC mains and turn on Power Switch , the Charger On LED and the Float LED should be on green indicating Charger is
in good order for charging lead acid battery.
Before connecting or disconnecting the charging cable, turn off the Power Switch and unplug AC cord  from the mains.
First connect the Red cable to Po terminal of charger and the battery Po Pole. Then connect the Black cable to the
Negative – terminal and the Negative – Pole of the battery.
Make sure all the connections are secured and well tighten up, double check on the correct polarity.
Double check again for correct selection of Slide Switch 1 at Charger Mode, Switch 2 for Battery type and  Switch 3 for Float
Voltage setting value.

D. Normal 3 Stage (IUoU) Charging Operation 

The 3 stage IU0U charge algorithm ensures fast , complete and at the same time gentle charging of the lead acid battery.

Fig.2

Содержание FUM-24 CBP Series

Страница 1: ...er serviceable parts inside Do not charge the battery on boats Remove the battery and charge on shore Never attempt to charge a frozen battery Never attempt to charge a damaged battery Wear protective...

Страница 2: ...Charger Power Supply Selection Slide Switch to set Charger to 3 Stage Charger or Power Supply Mode See Section G 3 Battery Type Selection Slide Switch to set charger for AGM Gel Wet and Calcium Calciu...

Страница 3: ...tery condition fill up cells for wet battery clean battery poles Secure the battery charger in a well ventilated place make sure the mounting surface is flat and without soft covering material or loos...

Страница 4: ...because only one setting of charging profile for both Two batteries are charged simultaneously and the battery with the lowest level gets most share of the current in the Bulk charge stage until it is...

Страница 5: ...s used to optimal charging over wide ambient temperature range Fix the temperature sensor optional accessory in a position on the battery which is not affected by other cooling or heating source Plug...

Страница 6: ...ours charging time Absorption light remains on all the time Wrong battery type selection eg charge gel battery with Calcium Calcium OR Wet type selection Total battery capacity is too high for dual ch...

Страница 7: ...ted Output Current or 50 Rated Output Current Soft Charge Protection Type Constant Current Limiting recovers Automatically after Fault Condition is Removed Short Circuit Recovers Automatically After F...

Отзывы: