7.1 - 

Wi-Fi :

 Wi-Fi converters (

TCP-485 Wi-Fi

 and 

TCP-485 Wi-Fi Log

) can be accessed through the       

    inbox

 in two ways:

Hotspot on

 : Converters can be configured to connect to the Wi-Fi network provided by the 

 inbox 

(without a Wi-Fi router).

Sitrad

 

Hotspot off

 : Converters are configured to connect to an existing Wi-Fi network (with a Wi--Fi router), and the 

 

 inbox

 accesses these 

Sit

converters through the same Wi-Fi network

7.2 - USB

 : Connect the USB cable to the

 inbox

 appropriate input. The other end of the cable should be connected to the 

CONV32

. It can be 

 

 

sitrad

directly connected to up to four USB converters in the 

        inbox

 , using the 

CONV32

 version 03 or higher. If version 01 or 02of 

CONV32

 is 

used only one USB can be connected.

7.3 - Ethernet

 : Connect the 

inbox

 to the router using an Ethernet cable (RJ-45). With another cable (RJ-45), connect the 

TCP-485

  

Sitrad

 

(Ethernet converter) to the same router.

              

7.4 - RS-485

 : Directly connect the first terminal block to inputs A and B of  

inbox

, maintaining the ‘’A-A, B-B’’ connection pattern. One 

Sitrad

terminal block must be used for each connected controller.

MT-530

MT-530

super

super

MT-530

MT-530

super

super

A

A

A

A

B

B

B

B

A

A

B

B

A

A

A

A

B

B

B

B

A

A

B

B

MT-530

super

MT-530

super

A

A

B

B

A B

A

A

B

B

A B

MT-530

super

MT-530

super

A

A

B

B

A B

A

A

B

B

A B

27

MT-530

super

A

A

B

B

A B

Hotspot on (without a Wi-Fi router)

 Hotspot off (with a Wi-Fi router)

MT-530

super

A

A

B

B

A B

x

     IMPORTANT: Hotspot is the operation mode in which 

 

inbox

 provides other devices with a Wi-Fi network infrastructure to connect to.

Sitrad

!

Содержание Sitrad INBOX

Страница 1: ...55 51 3475 3308 I www fullgauge com br inbox Ver 01 Supervisory HDMI system Serial Ethernet USB Wi Fi Server communication RS 485 SITRADINBOXV01 01T 17026...

Страница 2: ...roneofthemachinesisdisconnected theIPwillbefreeforuseinanother HDMI Stands for High Definition Multimedia Interface which is a digital audio and video conductive interface capable of transmitting unco...

Страница 3: ...ATION PRECAUTIONS Before performing any procedure on this instrument unplug it from the power grid Ensure that the instrument has adequate ventilation avoiding installation on panels containing device...

Страница 4: ...scribedinitems9and9 3 2 Checkthetemperatureoftheenvironmentwherethe inboxisinstalled Removeanysourcesofheatneartheequipment RS 485 Ethernet USB Wi Fi Power LED Power Button RS 485 network transmission...

Страница 5: ...CONV32 is usedonlyoneUSBcanbeconnected 7 3 Ethernet Connect the inbox to the router using an Ethernet cable RJ 45 With another cable RJ 45 connect the TCP 485 Sitrad Ethernetconverter tothesamerouter...

Страница 6: ...gistrationof inbox asserverisasfollow Sitrad 8 2 2 Afterconnectingtothe inbox network open Proandselecttheoption Registernewserver IMPORTANT The Ethernet Mode is independent of the others and can be u...

Страница 7: ...inbox and Pro are using the same network For more advanced settings use the Register new server Sitrad Sitrad option Inthiscase youneedtocontactyournetworkadministratortoconfiguretheIPsettings 8 4 Aft...

Страница 8: ...l in this field with the IPaddress of the server he she wants to be connected to Fill in the City and State fieldsanduseadminforthe User and Password fields 8 6 Afterenteringthedataon Serverregistrati...

Страница 9: ...From a mobile device access the network settings and connect to SitradinboxNet using the sitrad001 password the network name and passwordsettingscanbemodifiedlateraccordingtoitem9 10 Open a browser C...

Страница 10: ...provide a valid email address and then click Next If the provided email address has already been used the data relatingtothisaddressesregistrationwillbeloadedautomatically IMPORTANT In order to confi...

Страница 11: ...Next 9 2 3 Attheendoftheprocess click Register The Next and Register buttonsareavailableonlyifthedataenteredisvalid Merely illustrative images Merely illustrative images Producto not registered Regis...

Страница 12: ...itwillnotbepossibleto Sitrad performthisoperationagain 9 3 On the General tab you can configure the time zone where the inbox will be installed as well as the operating system s keyboard and sitrad l...

Страница 13: ...nnection s mode of operation in the inbox By clicking on Enable Hotspot Mode the program sitrad provides a wireless network structure for other devices to connect to it Otherwise the user must connect...

Страница 14: ...ailablethedataprovidedbythecontrollers FullGauge to Pro In this tab it is possible to perform the management by stopping or restarting it as necessary The user can also view information on available s...

Страница 15: ...When access is made Sitrad directlytothe inboxusingthemonitor thedownloadanduploadactionswillnotbeavailable Sitrad Subsequently backup files downloaded to other computers can be reloaded and re stored...

Страница 16: ...n The Log files contained in this tab refer to the actions taken from the configuration page Example date and time changes language setting etc Sitrad Service The Log files contained in this tab refer...

Страница 17: ...e Users field to display the user list screen This screen allows users to search add edit and delete users Only users with Super admin privilegescanaccessthe inboxsettingspage Sitrad Merely illustrati...

Страница 18: ...than2metersbetweentheconnectionblockandthecontroller Useamaximumof32devicesconnectedtoeachInterface 32 controllers 32 controllers MT 530 super MT 530 super MT 530 super MT 530 super CONVERTER RS 485 P...

Страница 19: ...arrangementstocreateawell definedpath Ceiling POWER STATUS TX RX Maximum 2 meters Ceiling CONVERTER RS 485 POWER STATUS TX RX Usedtointerconnectmorethanoneinstrumenttotheinterface Thewiresmustbeconnec...

Страница 20: ...super super super CORRECT 10 5IMPORTANT AccordingtochaptersofNBR5410standard 1 Installsurgeprotectorsonthepowerline 2 Serialcommunicationandsensorcablescanbeinstalledtogether butnotinthesameconduitwh...

Страница 21: ...a75mmdimension Thescrewusedmustbe M4cylindrical head slottedorPhilips atleast8mmlong 12 1 2 Afterpositioningtheinterface pushitdowntosecureit 43 12 2FASTENINGBYDINRAIL 12 2 1 To attach the interface t...

Страница 22: ...other kinds of expenses such asindemnityfordamagescausedtootherequipment WARRANTY EXCEPTIONS The Warranty does not cover expenses incurred for freight and or insurance for sending the products with si...

Отзывы: