manualshive.com logo in svg
background image

1. DESCRIPTION

2. APPLICATION

3. TECHNICAL SPECIFICATIONS

The

 

Microsol

 

FLT Advanced

 

 is a digital thermostat for solar heating that controls 

a water circulation pump through the temperature differential between the solar collector 
and the pool. It also features an auxiliary output, linked to the clock and events schedule, 
through  which  the  pool  can  be  filtered  at  predefined  times.  The  controller  includes 
functions to prevent overheating and freezing of water on the solar collector. Protected 
access to configuration parameters is also provided.
The 

Microsol 

Advanced

  line  is  characterized  by  its  unique  design  for  use  in 

residential environments, by the easiness of operation with keys for easy access to the 
controller's main resources and by the use of the custom display. The display technology 
employed allows presenting in a complete and simple manner the solar heating system's 
information,  such  as:  output  status,  pump  operation  mode,  and  sensor  position  and 
temperature. 

- Solar heating and filtering for pools.

- Power: Microsol 

FLT Advanced 

 

-10%(50/60Hz) or version -

10%(50/60Hz)

- Operation temperature: 

0 to 40ºC

- Operation humidity: 

10 to 90% UR (without condensation)

- Sensors: 

The 

Microsol

 

FLT Advanced 

has 2 sensors

:

Sensor T1:

 Solar Collector – SB59 Sensor, metal tip, Silicone, 1m

Sensor T2:

 Pool – SB41 Sensor, plastic tip, 2m

- Control temperature: Sensor T1: 

-50 to 200ºC / -58 to 392ºF

                                      

Sensor T2: 

-50 to 105ºC / -58 to 221ºF

- Resolution: 

0.1ºC between -10 and 100ºC and 1ºC in the remainder of the range 

1ºF in all of the range

- Control output: 

The 

Microsol

 

FLT Advanced

  has two relay outputs:

PUMP - 

Relay output, max. 1HP in 220Vca (½ HP in 127 Vca)

AUX - 

Relay output, max. 1HP in 220Vca (½ HP in 127 Vca)

- Dimensions: 

104 x 148 x 32 mm

- Display: 

LCD 2.75'' with backlight

:

5. OPERATIONS FOR DOMESTIC USER
5.1 KEY MAP

The controller has easy-access to user resources. Contains table with description of the 
following:

Short touch: adjust the pool/reservoir heating temperature

Long touch (4 seconds): access to advanced settings

Long touch (see F14 parameter): enables/disables function block

Short touch: switches temperature display (DIF, T1, T2) for 10 seconds

Short touch: switches pump mode (OFF / AUT / MAN)

Short touch: changes filtering mode (AUT / MAN)

Long touch (4 seconds): enables/disables filtering (OFF) mode

Short touch: accesses hour and day settings menu

Long touch: (4 seconds): accesses settings menu for event schedule  

DIFFERENTIAL THERMOSTAT

 FOR SOLAR HEATING

Ver. 01

SET

SET

FLT 

Advanced

 

4. INDICATIONS AND SCREEN

4.1 PRESENTATION

1
2
3
4
5
6
7
8
9

10
11
12

Pump mode key
Filtering mode key
Clock key
Lowering key
Set key
Increasing key
Indication of the pump operation mode
Indication of operating mode of the filtering output
Controller signals
Representation of the heating system and filtering
Lower display numbers
Upper display numbers

4.2 INDICATIONS

SET

LOC

In programming, cleared parameter setting
In programming, blocked parameter setting
Fahrenheit scale temperature Indication
Celsius scale temperature Indication
Pump turned on due to cooling function
Pump turned on due to antifreeze function
Pump turned on due to vacuum tube function
Pump turned on due to temperature differential (T1-T2)
Pump outlet turned on
Filtering pump output on

T1 Sensor Position - solar collector
T2 Sensor Position - thermal reservoir
Indicates overheating occurrence T1
Indicates sensor error occurrence T1
Indicates sensor error occurrence T2
Function block setting
Before noon (standard clock 12pm)
After noon (standard clock 12pm)

5.3 WATER PUMP OPERATION MODE

For every short touch on     key the water pump operation mode is switched. The water 
circulation pump between the solar collector and the thermal reservoir can operate in three
distinct modes. A description follows:
                                             
                                                        

                                                

Obs.:

 In the pump mode settings, the controller takes on the new mode 5 seconds after its 

selection. This also is the time necessary for the parameter to be stored in its memory.
When the MAN mode is selected (MANUAL), the operation mode remains in this state for 
the  period  of  6  hours  (fixed  time).  After,  the  controller  takes  on  the  AUT  mode 
(AUTOMATIC). If you wish to return to AUT mode before 6 hours, press the    key at any 
time.

off

PUMP

AUT

PUMP

MAN

PUMP

5.4 FILTERING OPERATING MODE

With each short press of the    button you can change the operating mode of the filtering 
output between AUT and MAN modes.

AUX

AUT

AUX

MAN

 OFF = Circulation pump always turned off

AUT = Circulation pump in automatic mode
operating according to parameter settings

 MAN = Circulation pump turned on

am

pm

+

+

+

SET

5.2 POOL/RESERVOIR HEATING TEMPERATURE (SENSOR T2)

Sets the comfort temperature of the pool or thermal reservoir. After reaching 
this temperature, the water circulation pump is turned off, avoiding thermal 
discomfort.
To adjust this parameter, short press the 

SET

 button. Use the    and    keys 

to adjust the value. To confirm, short press the 

SET

 button and the value will 

be saved in the controller memory. This parameter can be adjusted between 
0.0 and 105 °C or between 32 and 221 °F.

F

SET

1

2

3

6

5

4

7

8

12

9

10

11

F

F

F

F

F

MAX

FILTER

am pm

SET LOC

AUX

AUT

off

MAN

AUT

off

MAN

PUMP

am pm

MAX

FLT

F

FILTER

AUX

AUT

AUT

PUMP

Obs:

 the sum of the

loads should not

surpass 24A

Attention: 

In this mode the pump is maintained turned on,

ignoring the protection functions and temperature sensors.

Note: 

When adjusting the filtering mode, the controller changes into the new mode 5 

seconds after your selection. This is also the time required for the parameter to be stored in 
its memory.
Manual mode is used when you wish to filter the pool outside the hours set in the events 
schedule.

AUT = Filtering in automatic mode, operating 
according  to  the  configuration  of  the  events 
schedule.

MAN = Filtering in manual mode, output remains 
on for the time set in 

[,F10]

- Filtering manual 

override time, returning to AUT (automatic) mode 
after this time has elapsed.

MCSOLADV