2
3
REMOTE CONTROL
12V DC 8.3A
12 V APPLIANCE OUTLET 8.3A
5V DC USB
BATTERY POWER
OVERLOAD RUN LOW OIL
STOP
ECONOMY
ON
ON
OFF
240V
OFF
STOP
START
ON
DC OVERLOAD
RESET
Air cleaner service
•
•
•
To clean, remove the screws then remove outer casing.
Remove the foam element.
•
Wash the foam element in solvent and let dry.
•
Pour a small amount of oil on the foam element then squeeze out, but do not
wring out, excess oil. Foam element should be damp, but not dripping.
•
Do not run the generator without reinstalling the foam element or excessive piston and
CAUTION!
cylinder wear may result.
Spark plug servicing
•
Remove cap. Then remove spark plug cap.
•
Disconnect the spark plug wire from the spark plug.
•
Before removing the spark plug, clean the area around its base to prevent debris from
entering the engine.
•
Insert a spark plug socket wrench through the opening on the outside of the cover. Turn
the wrench counterclockwise.
•
Check for discoloration and clean carbon deposits off the electrode with a wire brush.
•
Check the electrode gap and slowly adjust to 0.
7
- 0.
8
mm (0.02
8
-0.0
31
in) if necessary.
•
Reinstall spark plug and tighten to Torque 20.0Nm (14.8ft-lb).
ON
Checking Spark Plug
•
If spark plug is worn replace only with an equivalent replacement part. Spark plug
should
be replaced annually.
•
Reconnect spark plug wire.
•
Replace spark plug cap, then replace cap.
Standard Spark Plug:
E6TC/E6RT/BPR
7
HS
Spark Plug Gap:
0.
7
- 0.
8
mm (0.02
8
-0.0
31
in)
Spark Plug Torque:
20.0Nm (14.8ft-lb)
0.
7
-
0.
8
mm
MAINTENANCE (cont.)
Содержание SD2200i
Страница 3: ...3 KNOW YOUR PRODUCT cont...
Страница 29: ...29...