Installation Instructions subject to change without notice.
Page 3 of 7
11/09/18
INS-FHEZ, Rev A
HotSpot EZ Exit
2. Locate the location where the EZ EXIT luminaire will
be installed and remove the surrounding ceiling tiles.
3. Identify your power source and junction box for the
driver and extension harness; be sure the junction box
is within the given distance of the extension harness.
4. Using your flat head screwdriver, pry the tabs apart on
each end of the piece of grid you are removing.
A. Be sure when you remove this piece you leave the tabs
from the opposite grid pieces in place; this will help align
your EZ Exit luminaire and keep it straight for the existing
tiles.
1. Locate and gather the necessary Tools and Contractor Supplied Materials:
A. Lineman, Wire Splicers, Flat Head Screwdriver
B. 8 Wirenuts, Supporting materials for the driver.
a. Driver can be installed different ways to meet each individual need:
• Surface mounted to a beam or wall
• Supported to ceiling drop wire with the (2) caddy clips supplied using (2) ¼-20 machine screws and hex nuts to bolt the
driver to the caddy clips when secured to the drop wire.
• Supported to (2) T-Grid Standoffs by installing the T-Grid Standoffs to the top of the grid and using (2) ¼-20 Machine Screws
and Hex Nuts to bolt the fixture to the standoffs.
Fulham Co. Inc.
: 12705 South Van Ness Ave., Hawthorne, CA 90250
Telephone
: 1-323-779-2980
Fax
: 1-323-754-9060
www.fulham.com