Warning Label
Make sure to read the warning label attached to the equipment and
comply with the requirements while operating the equipment.
CAUTION
Do not damage or erase the warning label attached to the
equipment.
The warning label contains important descriptions for handling
and operating the equipment properly and safely. A damaged
label may compromise safe operation.
MGU-811P
Graphic Symbols
The following are the symbols and their meaning indicated on the
equipment.
Symbol Description
Caution; refer to accompanying documents
Indicates the need to refer to related accompanying
documents before operation.
Type BF Applied Part with Defibrillation-Proof
Indicates the degree of protection against electric
shock which is Type BF Applied Part with
defibrillation-proof.
GAS Output
Indicates the position where it exhausts the
sampling gas.
Year of Manufacture
Indicates the manufactured year.
WEEE (Waste Electrical and Electronics Equipment)
Indicates a separate collection for electrical and
electronic equipment.
General Description
The MGU-810 series is a sidestream gas measuring unit. The
following model types are available according to the different
measurement parameters.
Model Type CO
2
/N
2
O
Agent GAS
Measurement
O
2
Measurement
Spirometry
MGU-811P Yes
Yes
Yes*
Yes
MGU-812 Yes
Yes
No
Yes
MGU-813
Yes No No Yes
* with the Servomex Paramagnetic Oxygen Sensor
This equipment is used for the specified patient monitor. The
contents to be displayed differ depending on the connected patient
monitor, thus refer to the patient monitor’s operation manual, the
DS-8500 System.
Features
Automatically detects the type of anesthetic gas for monitoring.
With the sidestream method, the patient connection part is
smaller, lighter and quieter.
CO
2
, N
2
O, five anesthetic agents (Halothane, Isoflurane,
Sevoflurane, Enflurane, and Desflurane), and O
2
concentration
can be measured.
Model types with/without the Agent GAS measurement and/or
O
2
measurement is available.
O
2
measurement uses a paramagnetic method.
Spirometry with the flow sensor allows measuring the Airway
Pressure, Tidal Volume, Airway Flow, Minute Volume, Airway
Compliance, Airway Resistance, and I:E ratio.
Name of Parts and Their Functions
WARNING
Do not connect a unit or cable not authorized by Fukuda Denshi to
any I/O connector. If done so by mistake, the equipment cannot
deliver its maximum performance and the connected units may be
damaged, resulting in a safety hazard.
Front Side
Rear Side
(1) Power Supply Indicator
Indicates the power status.
Green : Power is supplied to the MGU-810.
Light Off : When the power of the DS-8500 System, which is
connected to the MGU-810, is OFF, or the power supply
indicator on the display unit is orange (in standby mode).
(2) Inlet
Connects the gas sampling line of the SPRIT
™
Flow Sensor.
(3) DRYLINE™ Water Trap (with container)
Removes water inside the sampling tube connected to the patient.
Empty the water trap container when it is half full. When
connecting to a new patient, clean it with the specified disinfect
solution (refer to the “Cleaning” below). When removing the
water trap, press the side buttons.
(4) Exhaust Outlet
Connects gas exhaust system and exhausts sampling gas.
(5) Flow Sensor Connector
Connects the pressure line of the SPRIT
™
Flow Sensor.
(1)
(2)
(3)
(4)
(6)
(7)
(5)