Line
Function
Setting range
or display
Setting
increment
Basic
setting
850
I
Off
- Off: Early interruption of the current programme, programme inactive.
- Operational heating.
- Heating ready for occupation.
- Operational h ready heating.
- Ready h operational heating.
- Manual: Manual mode enables you to programme your own concrete slab drying time.The function ends
automatically after 25 days.
"
Please comply with the
standards and instructions
of the manufacturer of
the building ! A good
performance of this function
is only possible with an
installation
correctly
implemented
(hydraulic,
electricity and adjustments) !
This function can be stopped
by anticipation when setting
the adjustment to "Off" .
50
45
40
35
30
20
5
0
25
55
1
1
5
7
X
10
18
25
15
1
figure 1 - Diagram of the concrete slab drying programmes
Heating flow temperature °C
Operational h Heating ready for occupation
Heating ready for occupation
Day
Operational
heating
851
I
Floor curing setpoint manually
(if line 850 = manual)
0 95 °C
1 °C
25 °C
This function enables you to set the custom concrete slab drying temperature. This temperature remains fixed.
The concrete slab-drying programme stops automatically after running for 25 days.
856
I
Floor curing day current
0 32
857
I
Floor curing day completed
0 32
900
S
Operating mode changeover
None, Protection mode,
Reduced, Comfort, Automatic
1
Reduced
Operating mode at end of concrete slab drying period
Cooling circuit 1
If the installation is fitted with the cooling kit (Only with the cooling kit option).
901
U
Operating mode
Protection, Automatic, Reduced,
Comfort
Protection
902
U
Comfort cooling setpoint
17 40 °C
0,5 °C
24 °C
903
U
Reduced setpoint
5 40°C
26 °C
908
I
Flow temp setp at OT° 25°C
6 35 °C
0,5 °C
20 °C
909
I
Flow temp setp at OT° 35°C
6 35 °C
0,5 °C
16 °C
912
I
Cooling limit at OT°
8 35 °C
0,5 °C
24 °C
913
S
Lock time at end of heating / cooling
8 100
1 h
24 h
918
S
Summer comp start at OT°
20 50 °C
1 °C
26 °C
919
S
Summer comp end at OT°
20 50 °C
1 °C
40 °C
920
S
Summer comp setp increase
1 10 °C
1 °C
4 °C
923
S
Flow temp setp min OT° 25°C
6 35 °C
0,5 °C
18 °C
924
S
Flow temp setp min OT° 35°C
6 35 °C
0,5 °C
18 °C
Installation and operation manual "1764 - EN"
Air to Water Heat Pump, split system
- 54 -
Содержание WOYA060LFCA
Страница 23: ... Installation and operation manual 1764 EN 23 Air to Water Heat Pump split system ...
Страница 29: ... Installation and operation manual 1764 EN 29 Air to Water Heat Pump split system ...
Страница 33: ...Installation and operation manual 1764 EN 33 Air to Water Heat Pump split system ...
Страница 35: ... Installation and operation manual 1764 EN 35 Air to Water Heat Pump split system ...
Страница 71: ...Installation and operation manual 1764 EN 71 Air to Water Heat Pump split system ...
Страница 73: ... Installation and operation manual 1764 EN 73 Air to Water Heat Pump split system ...
Страница 79: ... Installation and operation manual 1764 EN 79 Air to Water Heat Pump split system ...
Страница 86: ...Installation and operation manual 1764 EN Air to Water Heat Pump split system 86 ...
Страница 87: ...Installation and operation manual 1764 EN 87 Air to Water Heat Pump split system ...
Страница 88: ...Installation and operation manual 1764 EN Air to Water Heat Pump split system 88 ...
Страница 89: ...Installation and operation manual 1764 EN 89 Air to Water Heat Pump split system ...
Страница 90: ...Installation and operation manual 1764 EN Air to Water Heat Pump split system 90 ...
Страница 91: ... Installation and operation manual 1764 EN 91 Air to Water Heat Pump split system ...