background image

En-2

 CAUTION

•  Be careful not to damage the parts on the board.

Otherwise, it will cause malfunction.

Connector number: CN 5
Connector number: CN 4
Connector number: CN 3

Connector number: CN 7

* : Symbol indicating the location printed on the board 

(4)  Remove the wires from the three fixtures. (See the figure below)

•  Leave the thick green wire in fixture C and remove the rest of the wires.

 CAUTION

•  Do not pull the wires forcibly.

You may damage them.

Fixture A

Before

After

Fixture B

Fixture C

Fixture C

(5)  While pulling the control box towards you, remove in the right direction.

•  Do not remove the thermistor.
•  Do not damage the terminals on the removed wires. (See the figure below)

Thermistor

Control box

Terminals

Control box

(5)

Installing communication box 

(1)  Install the communication box on the main unit and secure it with the provided

screw at the location shown below.

View A (Detail view)

Screw

Motor cover

View A (Detail view)

(2)  Use the hole on the motor cover and secure the wire from the communication box 

with the provided cable tie.

(See the figure below)

Cable tie

Cut away the tip of 

the cable tie.

Hole

Installing control box

(1) Set the control box toward the bottom so that it touches the motor cover from the

right.

Insert the protruding part of the main 

unit on the

 xture (1 location) into 

the control box.
Control box

• The installation method of the control box is different for each destination country. 

(See figure below)

(When installing, reuse the screw that was removed in

 

Removing control box

.) 

(2)  Secure the control box with a screw. (Use a long screw.)

9333005041_IM.indb 9

11/6/2013 10:33:06 AM

Отзывы: