background image

OptoLink A-CCP to OptoLink A-FCR, BCR or CCR receptacle

Step 1:   Inspect the connector face and O-rings  

              Grease the O-rings with Molykote 111

Step 2:   Inspect the connector surface. If the connector surface is 

 

dirty, follow the OptoLink maintenance instructions overleaf

Step 3:   Visually align the key way on the CCP connector with the  

 

key pin tip on the receptacle 

before

 mating (illustration A)

             

 

Do not twist the connector to align it during mating

Step 4:   Push to mate the connector (illustration B)

Step 5:   Whilst turning the locking sleeve (illustration C)

 

Note: The connector must be hand tightened

Assembly 

OptoLink Handling instructions

Follow these instructions carefully to ensure correct use of your 

OptoLink connector and penetrator harnesses.