1 MONITOR
1-1 Monitor
1-1-1 Monitor mode screen
Monitor Mode Screen is home screen of this unit.
76°F
80°F
74°F
84°F
68°F
Away
Custom
Auto
Auto
Cool
Heat
Office
Set Temp.
Mode
Menu
Status
Vacation
Fan
Fri 10:00AM
Room Temp.
Cool
Heat
Override
Occupied
(m)
(m)
(c)
(f)
(e)
(i)
(h)
(g)
(d)
(m)
(a)
(m)
(m)
(j)
(k)
(l)
(b)
(a) R.C. group name:
Name of the remote controller group to which this unit is
connected. Refer to [3 SETTING] → [3-8 Initial Setting]
→ [3-8-4 R.C.Group Name Setting].
(b) Clock:
Refer to [3 SETTING] → [3-8 Initial Setting] → [3-8-2
Date Setting].
(c) Mode:
When this is touched, the display switches to the “Mode”
screen. Refer to [2 CONTROL] → [2-2 Operation Set-
tings] → [2-2-1 Set the Operation Mode].
(d) Set temp.:
When this is touched, the display switches to the tem-
perature setting screen. Refer to [2 CONTROL] → [2-2
Operation Settings] → [2-2-2 Set the Temperature].
(e) Fan:
When this is touched, the display switches the fan speed
setting screen. Refer to [2 CONTROL] → [2-2 Operation
Settings] → [2-2-3 Set the Fan Speed].
(f) Away:
When “Away” is enabled, the start temperature of “Away”
operation is displayed when unoccupied. When “away”
is operating, “Away Operation” is displayed.
Refer to [3 SETTING]→[3-5 Special Setting]→[3-5-5
Away Setting].
(g) Room Temp.:
This unit ambient temperature sensed by this unit is
displayed. Refer to [3 SETTING] → [3-8 Initial Setting]
→ [3-8-7 Display Item Setting].
(h) Override:
Displayed while the following functions are operating:
• Auto Off Timer:
Refer to [3 SETTING]→[3-3 Auto Off Timer Setting].
• Set Temp. Auto Return:
Refer to [3 SETTING]→[3-5 Special Setting]→[3-5-2
Set Temp. Auto Return].
(i) Occupied state:
“Occupied” or “Unoccupied” is displayed according to
the operation of Operation button or schedule setting.
(j) Menu:
When this is touched, the display switches to the “Menu”
screen. Refer to [3 SETTING].
(k) Status:
When this is touched, the display switches to the “Status”
screen. Refer to [1-1-2 Status Display].
(l) Vacation:
When this is touched, the schedule is disabled and the
indoor unit remains unoccupied. Refer to [1-1-3 Vaca-
tion]. “Vacation” is displayed only when a schedule is
set.
(m) Status icons:
Indoor Unit Stop is enabled. Refer to [1-1-5 Indoor
Unit Stop].
The error occurred. Refer to [5 OTHERS] → [5-3
Error Code].
Operation from this unit is prohibited by the Central
Controller. Refer to [1-1-2 Status Display].
Mode mismatch. The mode which cannot operate
simultaneously is selected. Refer to [1-1-2 Status
Display].
“Custom Auto Mode” or “Away” does not work.
Verify the following settings:
• R.C. Sensor Setting
Refer to [3 SETTING] → [3-8 Initial Setting] →
[3-8-5 R.C. Sensor Setting].
• Master Indoor Unit Setting (For installer)
Consult authorized service personnel.
When the remote controller that uses a sensor is
changed in the master indoor unit or R.C. Group,
change the operation mode or disable “Away”.
The Auto Off Timer is set. Refer to [3 SETTING] →
[3-3 Auto Off Timer Setting].
The weekly timer is set. Refer to [3 SETTING] →
[3-4 Weekly Timer Setting].
The set temperature automatic return setting is set.
Refer to [3 SETTING] → [3-5 Special Setting] →
[3-5-2 Set Temp. Auto Return].
It shows that it is time to clean the filter. Refer to
[3 SETTING] → [3-9 Maintenance] → [3-9-3 Filter
Sign Reset].
The temperature sensor of this unit is used. Refer
to [3 SETTING] → [3-8 Initial Setting] → [3-8-5 R.C.
Sensor Setting].
For the screen display other than Chinese, this product
uses a Bitmap font made and developed by Ricoh Com-
pany, Ltd.
1-1-2 Status display
The remote controller and indoor unit setting status are dis-
played.
Touch the [Status] on monitor
mode screen. “Status” screen is
displayed.
76°F
80°F
74°F
84°F
68°F
Custom
Auto
Auto
Cool
Heat
Set Temp.
Mode
Menu
Status
Vacation
Fan
Fri 10:00AM
Room Temp.
Cool
Heat
Away
Occupied
The “Status” screen has 2, 3 or 4 pages which are switched
by touching the [Next Page] or [Previous Page]. When the
[Monitor] is touched, the display returns to the monitor mode
screen.
(*: Items that indoor unit does not support are not displayed.)
En-5
En-6
Содержание UTY-RNRUZ2
Страница 26: ......