En-5
Room temperature is controlled by either indoor unit tem-
perature sensor or remote controller unit sensor.
9) Remote controller signal code
Change the indoor unit Signal Code, depending on the re-
mote controllers.
(
♦
... Factory setting)
Setting description
Function
number
Setting
value
♦
A
44
00
B
01
C
02
D
03
10) External input control
“Operation/Stop” mode or “Forced stop” mode can be se-
lected.
(
♦
... Factory setting)
Setting description
Function
number
Setting
value
♦
Operation/Stop mode
46
00
(Setting forbidden)
01
Forced stop mode
02
11) Room temperature control switching
(Only for Wired remote controller)
This setting is used to set the room temperature control
method when the wired remote controller is selected by the
Indoor Room Temperature Sensor Switching Function.
(
♦
... Factory setting)
Setting description
Function
number
Setting
value
♦
Control by the sensors of
both the indoor unit and the
wired remote controller.
48
00
Control only by the sensor of
the wired remote controller
01
12) Setting record
Record any changes to the settings in the following table.
After completing the FUNCTION SETTING, be sure to turn
off the power and turn it on again.
Setting Value
Setting Description
Filter sign
Cooler room temperature
correction
Ceiling height
Outlet directions
Static pressure
Heater room temperature
correction
Auto restart
Indoor room temperature
sensor switching function
External input control
Remote controller signal code
Room temperature control
switching
5. SELECTING THE REMOTE
CONTROLLER SIGNAL CODE
When two or more air conditioners are installed in a room and
the remote controller is operating an air conditioner other than
the one you wish to set, change the signal code of the remote
controller to operate only the air conditioner you wish to set
(4 selections possible).
When two or more air conditioners are installed in a room, please
contact your retailer to set the individual air conditioner signal codes.
Selecting the remote controller signal code
Use the following steps to select the signal code of the remote
controller. (Note that the air conditioner cannot receive a
signal code if the air conditioner has not been set for the
signal code.)
(1) Press the START/STOP button until only the clock is
displayed on the remote controller display.
(2) Press the MODE button for at least 5 seconds to display
the current signal code (initially set to ).
(3) Press the SET TEMP. (
) (
) button to change the
signal code between
.
Match the code on the display to the air conditioner signal
code.
(4) Press the MODE button again to return to the clock
display. The signal code will be changed.
If no buttons are pressed within 30 seconds after the signal
code is displayed, the system returns to the original clock
display. In this case, start again from step 1.
The air conditioner signal code is set to A prior to shipment.
Contact your retailer to change the signal code.
The remote controller resets to signal code A when the
batteries in the remote controller are replaced. If you use a
signal code other than signal code A, reset the signal code
after replacing the batteries.
If you do not know the air conditioner signal code setting, try
each of the signal codes (
) until you
fi
nd the code
which operates the air conditioner.
9371972084-02_IM_en.indd 5
9371972084-02_IM_en.indd 5
9/7/2010 7:20:26 PM
9/7/2010 7:20:26 PM