Fujitsu UTY-LNHUM Скачать руководство пользователя страница 3

En-3

STEP 2

SELECTING THE FUNCTION NUMBER AND SETTING 
VALUE
Refer to the indoor unit installation manual for details on the 
function numbers and setting values.

Selecting the function number and setting value

(1)  Press the SET TEMP. (

) (

) buttons to select the 

function number.

 

(Press the MODE button to switch between the left and 
right digits.)

(2)  Press the FAN button to proceed to setting the value.
 

(Press the FAN button again to return to the function 
number selection.)

(3)  Press the SET TEMP. (

) (

) buttons to select the 

setting value.

 

(Press the MODE button to switch between the left and 
right digits.)

(4)  Press the TIMER MODE button, and START/STOP 

button, in the order listed to con

fi

 rm the settings.

(5)  Press the RESET button to cancel the function setting 

mode.

(6)  After completing the FUNCTION SETTING, be sure to 

turn off the power and turn it on again.

Function number

Setting 

value

 

CAUTION

After turning off the power, wait 10 seconds or more before 
turning on it again.
The FUNCTION SETTING doesn’t become effective if it 
doesn’t do so.

Function details

Functions

Function 

number

Compact 

cassette

Slim 
duct

Compact 

wall 

mounted

Wall 

mounted

1) Filter sign

11

z

z

 *1

z

z

2) Ceiling height

20

z

3) Outlet directions

22

z

4)

Static 
pressure

z

5)

Cooler room 
temperature 
correction

30

z

z

z

z

6)

Heater room 
temperature 
correction

31

z

z

z

z

7) Auto restart

40

z

z

z

z

8)

Indoor room 
temperature 
sensor switching 
function

42

z

z

z

z

(1) Mount the holder.

Screws

(2) Set the remote controller.

Insert

Press in

(3) To remove the remote controller (when use at hand).

Slide up

Pull out

4. FUNCTION SETTING

Perform the “FUNCTION SETTING” according to the installa-
tion conditions using the remote controller.

Entering the function setting mode

While pressing the FAN button and SET TEMP. (

• 

simultaneously, press the RESET button to enter the 
function setting mode.

STEP 1
Selecting the remote controller signal code

Use the following steps to select the signal code of the remote 
controller. (Note that the air conditioner cannot receive a 
signal code if the air conditioner has not 
been set for the signal code.)
The signal codes that are set through 
this process are applicable only to the 
signals in the FUNCTION SETTING. 
For details on how to set the signal 
codes through the normal process, 
refer to 5. SELECTING THE REMOTE 
CONTROLLER SIGNAL CODE.

(1)  Press the SET TEMP. ( ) ( ) 

button to change the signal code 
between 

 

Match the code on the display to the air conditioner signal 
code. (initially set to  )

 

(If the signal code does not need to be selected, press the 
MODE button and proceed to STEP 2.)

(2)  Press the TIMER MODE button and check that the indoor 

unit can receive signals at the displayed signal code.

(3)  Press the MODE button to accept the signal code, and 

proceed to STEP 2.

The air conditioner signal code is set to A prior to shipment. 
Contact your retailer to change the signal code.

The remote controller resets to signal code A when the 
batteries in the remote controller are replaced. If you use a 
signal code other than signal code A, reset the signal code 
after replacing the batteries.
If you do not know the air conditioner signal code setting, try 
each of the signal codes (

) until you 

fi

 nd the code 

which operates the air conditioner.

9371972084-02_IM_en.indd   3

9371972084-02_IM_en.indd   3

9/7/2010   7:20:24 PM

9/7/2010   7:20:24 PM

Содержание UTY-LNHUM

Страница 1: ...NTROLLER 2 3 1 Load batteries R03 LR03 x 2 2 3 2 Installing the remote controller holder 2 4 FUNCTION SETTING 3 5 SELECTING THE REMOTE CONTROLLER SIGNAL CODE 5 6 TEST OPERATION 6 INSTALLATION MANUAL For authorized service personnel only English Français Español 9371972084 02_IM_en indd 1 9371972084 02_IM_en indd 1 9 7 2010 7 20 14 PM 9 7 2010 7 20 14 PM ...

Страница 2: ...atteries When not using the Remote Controller for an extended period remove the batteries to avoid possible leakage and damage to the unit If leaking battery fluid comes in contact with your skin eyes or mouth immediately wash with copious amounts of water and consult your physician Dead batteries should be removed immediately and disposed of properly either in a battery collection receptacle or t...

Страница 3: ...ll out 4 FUNCTION SETTING Perform the FUNCTION SETTING according to the installa tion conditions using the remote controller Entering the function setting mode While pressing the FAN button and SET TEMP simultaneously press the RESET button to enter the function setting mode STEP 1 Selecting the remote controller signal code Use the following steps to select the signal code of the remote controlle...

Страница 4: ...e No 42 00 Yes 01 If setting value is 00 Room temperature is controlled by the indoor unit tempera ture sensor If setting value is 01 9 Remote controller signal code 44 z z z z 10 External input control 46 z z z z 11 Room temperature control switching 48 z z z z 1 It is effective only to install IR Receiver unit 1 Filter sign The indoor unit has a sign to inform the user that it is time to clean t...

Страница 5: ...led in a room and the remote controller is operating an air conditioner other than the one you wish to set change the signal code of the remote controller to operate only the air conditioner you wish to set 4 selections possible When two or more air conditioners are installed in a room please contact your retailer to set the individual air conditioner signal codes Selecting the remote controller s...

Страница 6: ...conditioner is running Point the transmitter section of the remote controller toward the air conditioner and press the test run button with the tip of a ball point pen etc Transmitter section Test run button To end test operation press the remote controller START STOP button 9371972084 02_IM_en indd 6 9371972084 02_IM_en indd 6 9 7 2010 7 20 26 PM 9 7 2010 7 20 26 PM ...

Отзывы: