115
CHAPTER2 Dependence Functions
Notes:
•
In the DSU3 chip, the code event can be used as a break factor and a trace measurement start
factor. This mode is called a trace sampling mode. There are two trace sampling modes.
- Full mode: The code event is used as a break factor.
- Trigger mode: The code event is used as a trace measurement start factor.
To use the code event as a break factor, set the full mode.
Set as follows:
Command
- SET TRACE/FULL
For details, refer to "4.12 SET TRACE (type 2)" in "SOFTUNE Workbench Command
Reference Manual".
Dialog
- Trace setting dialog
For details, refer to "4.4.8 Trace” in "SOFTUNE Workbench Operation Manual".
•
This function cannot be used when the FR60Lite is used. For details, refer to "2.3.4 Break".
Содержание SOFTUNE
Страница 2: ......
Страница 3: ...FUJITSU SEMICONDUCTOR LIMITED FR FAMILY SOFTUNE TM WORKBENCH USER S MANUAL for V6 ...
Страница 4: ......
Страница 42: ...32 CHAPTER1 Basic Functions ...
Страница 225: ...215 INDEX INDEX The index follows on the next page This is listed in alphabetic order ...
Страница 232: ...222 INDEX ...
Страница 234: ......