SK-MB9EF120-002,-003
Connectors
© Fujitsu Semiconductor Europe GmbH
- 17 -
UG-9E0010-11
5 Connectors
The following table lists the location of all connectors on the board. The pin-out of each connector is
listed in separate sections.
Name
Type
Description
Position
CN1
SAMTEC QSH-090-01-
L-D-A
board-to-board connector. Allows to connect a Multi-IO board
or any other matching I/O-board.
bottom Q-4:13
CN2
SAMTEC QSH-090-01-
L-D-A
B2B, Further signals from the MCU.
bottom B-4:13
X2
2*10 2.54mm IDC
header (male)
Standard ARM 20pin debug-header with JTAG-interface.
Must not be connected at the same time as X3.
top H:M-15
X3,4
TYCO 5767054-1
38pin connector for standard ARM trace interface (16 bits).
Includes also JTAG. Must not be connected at the same time
as X2.
top F:N-13
X1
DC-plug
2.1mm pin DC plug for external power-supply.
top C/D-14:16
X5
9pin Dsub male
CAN-Bus connector with standard-pinout.
top F:J-1:4
X6
USB Mini-B plug
USB device-plug to connect a PC with USB-Serial protocol
driver.
top O/P-2/3
The two B2B connectors provide all MCU ports, power supplies and control-signals.
5.1 B2B Connectors (CN1, CN2)
These two connectors provide all signals to a plug-under board like the Multi-IO-Board. Signals
include all MCU ports as well as reset and power supplies from the SK-board.
Signals are always routed to these connectors, even if they are used on the SK-MB9EF120-002,-003
themselves. When using a signal on a plug-under board which is also connected to an on-board
peripheral or connector, it must be disconnected from the on-board resource by pulling the
corresponding jumper. Some signals can be disconnected separately, while other signals are
disconnected as a whole function-block.
Fitting mates for the other board are SAMTEC QTH type connectors.
5.1.1 CN1 Pinout
Special Signals
Pin(s)
Signal
Description
1,2,6,7,12,13,54,55,
65,66,97,98,101,102,109,110,113,
137,138,162,167,171,172,
Shield
GND
System Ground
3-5,8-11,14-53,67-96, 100, 119
n.c.
not connected
103,105,107
reserved
do not use
104,106,108
VDP5
VDP5 power domain
164,166,168,170
5V0
5.0V power rail
173,175,177,179
Vin
Raw input power (after the power-switch,