ServerView Event Manager
31
iRMC S2/S3 SEL Entries and SC2 MIB Traps
07000A ’PSU XY’: Power
supply critical
temperature
Temperature at
power supply ’PSU
XY’ in cabinet XY of
server XY has
reached the critical
level.
2037 sc2TrapPower
SupplyCritical
Temperature
07000F ’PSU XY’: Power
supply fan prefailure
Fan failure is
predicted at power
supply ’PSU XY’ in
cabinet XY of server
XY.
2038 sc2TrapPower
SupplyFan
Failure
Prediction
0C0004 ’CPU XY’: CPU
internal error (IERR)
Internal error (IERR)
occurred on CPU
’CPU XY’ in cabinet
XY of server XY.
2082 sc2TrapCpu
Ierr
0C0021 ’CPU XY’:
Uncorrected CPU
Machine Check
Architecture (MCA)
error
0C0007 ’CPU XY’: CPU clock
automatically
throttled
CPU speed at server
XY changed to XY
percent of its
maximum speed.
2080 sc2TrapCpu
Speed
Changed
0C0017 ’CPU XY’: CPU
failure predicted
CPU failure is
predicted for CPU
’CPU XY’ in cabinet
XY.
2081 sc2TrapCpu
Prefail
0C000B ’CPU XY’: CPU
disabled
CPU ’CPU XY’ in
cabinet XY of server
XY is disabled.
2083 sc2TrapCpu
Disabled
Error
code
iRMC S2/S3 SEL
entry
Trap text
Trap
no.
Trap name
Table 4: iRMC S2/S3 SEL entry - SC2 MIB trap
Содержание ServerView Event Manager
Страница 6: ...ServerView Event Manager Contents ...
Страница 12: ...12 ServerView Event Manager Notational conventions ...
Страница 18: ...18 ServerView Event Manager Icons ...
Страница 80: ...80 ServerView Event Manager Alarm configuration example ...
Страница 168: ...168 ServerView Event Manager Trap overview ...
Страница 172: ...172 ServerView Event Manager MIB integration ...