ServerView Event Manager
149
Trap overview
tapeAlertTrap23
23
The last cleaning cartridge
used in the tape drive was
an invalid type:
1. Do not use this cleaning
cartridge in this drive.
2. Wait for the current
operation to finish.
3. Then use a valid
cleaning cartridge.
critical
tapeAlertTrap29
29
Preventive maintenance of
the tape drive is required.
Check the tape drive users
manual for device specific
preventive maintenance
tasks or call the tape drive
supplier helpline.
minor
tapeAlertTrap30
30
The tape drive has a
hardware fault:
1. Eject the tape or
magazine.
2. Reset the drive.
3. Restart the operation.
critical
tapeAlertTrap31
31
The tape drive has a
hardware fault:
1. Turn the tape drive off
and then on again.
2. Restart the operation.
3. If the problem persists,
call the tape drive
supplier helpline.
critical
Trap name
ID
Meaning
Error class
Table 44: Tape traps