4-28
(d) FM (file mark): Byte 2
This scanner does not support FM. This scanner returns B'0'.
(e) EOM (end of medium): Byte 2
Indicates the completion of window reading: 1 when completed, 0 when not completed.
(f) ILI (incorrect length indicator): Byte 2
Indicates that an error in logical block length has been detected.
(g) Sense key: Byte 2
Indicates the logical unit status using a sense key. This scanner supports the sense keys shown in the following
table:
Table 4-12
Sense key
status of logical unit
0
NO SENSE
The
logical
unit has no information to be specifically described in a sense key.
This status occurs because either a command has succeeded, or because a
command has terminated in the CHECK CONDITION status since tile ILI bit has
been set to 1.
2
NOT READY
The specified logical unit cannot be accessed.
3
MEDIUM ERROR
A command has terminated because of a trouble with tile medium. Typical
causes of this error with this scanner are that tile ADF paper chute is empty,
paper is jammed in the ADF, or the ADF cover has been opened.
4
HARDWARE ERROR
An unrecoverable error was detected
5
ILLEGAL REQUEST
An illegal parameter exists either in a command (CDB), or in a group of
parameters sent in the DATA OUT phase following a command.
6
UNIT ATTENTION
The target has been reset.
B
ABORTED COMMAND
The target has aborted a command.
(h) Information bytes: Bytes 3 to 6
The information in this field is effective if
ILI is 1. This scanner returns the remainder (2's complement any
negative value) so tile requested transfer amount subtracted by tile actual transfer amount
(i) Additional sense length: Byte 7
Specifies the number of sense bytes that follows. Even if all additional sense bytes cannot be transferred because
the allocation length in CDB is small, the value in this field is not adjusted to indicate the remaining data. This
scanner always assumes ~0A'.
Содержание Scan Partner 300C
Страница 1: ...Fujitsu ScanPartner 300C OEM Manual Version 1 0 Fujitsu Inc ...
Страница 12: ...3 2 1 Remove the shipping retainer 2 Fasten the shipping retainer ...
Страница 19: ...3 9 3 5 3 Readable area Feeding direction Unit mm Figure 3 5 ADF readable area 356 216 ...
Страница 26: ......
Страница 88: ......