2-2
2.2
Environmental Specifications
Table 2.2 lists the environmental specifications.
Table 2-2 Environmental Specifications
No.
Item
Specifications
Remarks
1
Physical
dimension
(mm)
Height
165
±
2mm
6.3
±
0.08 inches
Width
568
±
2mm
22.36
±
0.08
inches
Depth
348
±
2mm
13.7
±
0.08 inches
2
Weight
13.3 kg
24.89 lbs
3
Power
requirements
Voltage (VAC)
100- 240V (Auto switching)
Frequency (Hz)
47 to 63
Power cable
length (m)
3 or less
4
Power
consumption
(watts)
Operating
25 watts
Non-operating
14 watts
5
Acoustic noise (dB)
Operating: 56 dBA or less
Standby: 46 dBA or less
6
Temperature
(
º
C)
Operating
10 to 40
º
C (50
º
F to 104
º
F)
Gradient: 10
º
C/hr.
(18
º
F/hr.)
Non-operating
-40 to 60
º
C(-40
º
F to 140
º
F)
7
Relative
humidity (%)
Operating
10% to 90% RH
No condensation
Non-operating
10 to 90 RH
8
Vibration (G)
Operating
0.25
5-22-500 Hz
Direction = 3 Axial
Non-operating
1.0
9
Safety Regulations
UL1950, 3rd Edition
CSA C22-2 No. 950-M93
European Norm
EN 60950: 1988+A1+ A2
10
EMC
FCC Part 15 Subchapter J Class B
DOC Class B (Canada)
European Directive 89/336 (CE-Mark)