![Fujitsu RCF24LBL Скачать руководство пользователя страница 14](http://html.mh-extra.com/html/fujitsu/rcf24lbl/rcf24lbl_installation-manual_2343970014.webp)
En-14
Setting Other Functions
The following settings are also possible, depending on the
•
operating conditions. (The setting value is factory-set to
“00”.)
Auto Restart
•
Setting Description Function Number
Setting Value
Yes
40
00
No
01
Indoor Room Temperature Sensor Switching Function
•
(Wired remote controller only)
Setting Description Function Number
Setting Value
No
42
00
Yes
01
If setting value is “00”, room temperature is controlled by
•
the indoor unit temperature sensor.
If setting value is “01”, room temperature is controlled by
•
either indoor unit temperature sensor or remote control
unit sensor.
Setting record
Record any changes to the settings in the following table.
•
Setting
Setting Value
Ceiling height
Outlet directions
Filter sign
Cooler room temperature
correction
Heater room temperature
correction
Auto restart
Indoor room temperature
sensor switching function
After completing the FUNCTION SETTING, be sure to turn off
the power and turn it on again.
9.2. Function setting
Setting the Ceiling Height
Select the setting values in the table below according to
•
the height of the ceiling. (The setting value is factory-set to
“00”.)
Setting Description Function Number
Setting Value
Standard
(2.7 m)
20
00
High ceiling
(3.0 m)
01
The ceiling height values are for the 4-way outlet.
Do not change this setting in the 3-way outlet mode.
Setting the Outlet Directions
Select the setting values in the table below for using a 3-way
•
outlet. (The setting value is factory-set to “00”.)
Setting Description Function Number
Setting Value
4-way
22
00
3-way
01
Setting the Filter Sign
The indoor unit has a sign to inform the user that it is time to
•
clean the
fi
lter.
Select the time setting for the
fi
lter sign display interval in the
•
table below according to the amount of dust or debris in the
room. (The setting value is factory-set to “00”.)
If you do not wish the
fi
lter sign to be displayed, select the
•
setting value for “No indication”.
Setting Description Function Number
Setting Value
Standard
(2,500 hours)
11
00
Long interval
(4,400 hours)
01
Short interval
(1,250 hours)
02
No indication
03
Setting the Cooler Room Temperature Correction
Depending on the installed environment, the room tempera-
•
ture sensor may require a correction. The settings may be
selected as shown in the table below. (The setting value is
factory-set to “00”.)
Setting Description Function Number
Setting Value
Standard
30
00
Lower control
01
Setting the Heater Room Temperature Correction
Depending on the installed environment, the room tempera-
•
ture sensor may require a correction. The settings may be
changed as shown in the table below. (The setting value is
factory-set to “00”.)
Setting Description Function Number
Setting Value
Standard
31
00
Lower control
01
Slightly warmer control
02
Warmer control
03