9.7.4
Replacing a riser card
Field Replaceable Unit
(FRU)
Hardware: 5 minutes
Hardware: 5 minutes
Tools:
Phillips PH2 / (+) No. 2 screw driver
Preliminary steps
▶
"Locating the defective server" on page 47
▶
"Shutting down the server" on page 49
.
▶
"Disconnecting the power cord" on page 50
.
▶
"Getting access to the component" on page 51
▶
"Locating the defective component" on page 48
▶
Remove the corresponding riser module, see
.
Removing the defective riser card
▶
Remove all expansion cards installed in the riser module, see
the expansion card from the riser module" on page 367
.
▶
"Removing the riser card" on page 84
Installing a new riser card
▶
"Installing the riser card" on page 85
▶
Install all expansion cards in the riser module, see
card in the riser module" on page 369
.
Concluding steps
▶
Install the corresponding riser module, see
"Installing the riser module" on
▶
Expansion cards and backup units
TX2550 M5
Upgrade and Maintenance Manual
371
Содержание PRIMERGY TX2550 M5
Страница 20: ...Content Upgrade and Maintenance Manual TX2550 M5 ...
Страница 106: ...Basic hardware procedures 106 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 322: ...Fans 322 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 392: ...Expansion cards and backup units 392 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 408: ...Main memory 408 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 428: ...Processor CPU 428 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 522: ...System board and components 522 Upgrade and Maintenance Manual TX2550 M5 ...
Страница 590: ...FUJITSU Server PRIMERGY TX2550 M5 System Cabling Overview System Cabling Overview English Cable plan for May 2019 ...
Страница 631: ...List of all used screws for PRIMERGY Servers Assembled in Germany and Japan February 2019 ...