System configurator and order-information guide
PRIMERGY TX200 S7 Status 2014-01-30
K
2.5" HDDs for SFF base units; SAS or more than 4 SATA HDDs require a RAID Controller! See section VIII internal Disk Array
Up to 8 SFF (2.5") hard disks can be configured.
With the HDD Extension Box Option D up to 16 SFF (2.5") hard disks can be configured.
With the HDD Extension Box Option D 2 hardware based RAID controllers have to be configured.
The On board SATA Controller can be used with up to 4x 2.5" SATA HDDs (no additional controller required)
If a SAS based backup is configured, then the 4 onboard SATA ports for HDDs are not available any more!
In this case for any HDD solution a PCI based 8port RAID controller is necessary!
For up to 4x 2.5" SAS HDDs with RAID 0/1 functionality a Patsburg Upgrade Kit is required (no SAS tape option)
For up to 4x 2,5" HDDs in combination with a SAS tape or for all other HDD configurations a PCI based
RAID-controllers is required;
Mixed configurations with Eco SATA drives and SAS drives are not allowed
2.5" SAS drives and 2.5" BC SATA drives can be mixed, but not used in one logical RAID volume
Hot replace is only possible running RAID.
Mixed configuration 2.5" BC-SATA/BC-SAS with SAS 10K (S26361-F4483-E130/E145/E160) drives not allowed.
2.5" SAS drives and 2.5" BC SATA drives can be mixed, but not used in one logical RAID volume
S26361-F2826-E426
To be used in
SFF (2.5") HDD-Box for additional
SAS SFF (2.5") Base Unit only
8x SFF (2.5") SAS hard disks
see Conf. diagram
Option D
1x
Occupies 2x 1.6" bays
in the accessible bay area
For the 8x 2.5" HD Extension Box
3.2 * 5.25", satin black bezel
2 PCI based modular RAID controller is necessary
max. 1x per system
see Section VIII
S26361-F2826-E140
For a later configuration of more than 4 SATA HDDs, the trigger is not necessary
Trigger to request a PCI SAS Controller
In this case it is sufficient to implement a SAS controller!
for configuring more than 4
SATA
HDDs
It is not allowed to connect the SATA HDDs to different controllers
max. 1x per system
In case of running more than 4 HDDs, all of them have
to be connected to the PCI based Controller
as long as stock
S26361-F4541-E100
S26361-F4541-E400
**) High Endurance
SSD SAS 100GB, SLC
SSD SAS 400GB, SLC
100GB: max 9PB***,
Solid State Disk, SAS 6Gb/s
Solid State Disk, SAS 6Gb/s
random write
Enterprise Perfomance
Enterprise Perfomance
400GB: max 35PB***,
High Endurance **
High Endurance **
random write
hot plug/hot replace tray
hot plug/hot replace tray
max. 8/16x per system
max. 8/16x per system
as long as stock
as long as stock
S26361-F4581-E100
S26361-F4581-E200
S26361-F4581-E400
*) Mainstream
SSD SAS 100GB, MLC
SSD SAS 200GB, MLC
SSD SAS 400GB, MLC
Endurance
Solid State Disk, SAS 6Gb/s
Solid State Disk, SAS 6Gb/s
Solid State Disk, SAS 6Gb/s
10DWPD over 5y
Enterprise Performance
Enterprise Performance
Enterprise Performance
Mainstream Endurance *
Mainstream Endurance *
Mainstream Endurance *
Managed Life
hot plug/hot replace tray
hot plug/hot replace tray
hot plug/hot replace tray
Model
max. 8/16x per system
max. 8/16x per system
max. 8/16x per system
Solid State Disk Drive, Mainstream Endurance*
SSD
SAS 12Gb/s
2.5" with hot plug/hot replace tray
as soon as available
200GB, Enterprise Performance
S26361-F5297-E200
Interface SAS12Gb/s and SAS 6Gb/s.
400GB, Enterprise Performance
S26361-F5297-E400
SAS 12Gb/s support is not released
800GB, Enterprise Performance
S26361-F5297-E800
1.6TB, Enterprise Performance
S26361-F5297-E160
max. 8/16x per system
*) SSD Mainstream Endurance
10DWPD over 5y
K1
Fujitsu PRIMERGY Server
20 of 28