Fujitsu PRIMERGY TX200 S7 Скачать руководство пользователя страница 2

System configurator and order-information guide

PRIMERGY TX200 S7           Status 2014-01-30

Instructions

This document contains basic product and configuration information that will enable you to configure your system via
PC-/System-Architect

Only these tools will ensure a fast and proper configuration of your PRIMERGY server or your complete 
PRIMERGY Rack system.

You can configure your individual PRIMERGY server in order to adjust your specific requirements.

The System configurator is divided into several chapters that are identical to the current price list and PC-/System-Architect.

Please follow the lines. If there is a junction, you can choose which way or component you would like to take. Go through 
the configurator by following the lines from the top to the bottom.

Section

III

Memory, example

There are X memory slots which can be equipped with XXX MB

It is permissible to make up to X passes through the memory upgrade options

S26361-XXX-XXX

S26361-XXX-XXX

Memory XXX MB

Memory XXX MB

X times

max. X times per system

max. X times per system

In one chapter you can only select as many components (here 4x) as the arrow indicates.

4x

Please note that there are information symbols which indicate necessary information.

Further information in the internet see:

http://ts.fujitsu.com/products/standard_servers/index.html

(internet)

https://partners.ts.fujitsu.com/com/order-supply/configurators/primergy_config/current/Pages/default.aspx

(extranet)

Prices and availability see price list and PC-/System-Architect.
Subject to change and errors excepted.

Fujitsu PRIMERGY Server

2 of 28

Содержание PRIMERGY TX200 S7

Страница 1: ...software I Basic unit II Processor III Memory IV Graphics V Accessible drives VI Hard disk drives VII External SAS or SCSI Disk Array VIII Internal Disk Array IX Fiberchannel X Communication Network XI System Management Products RemoteView XII Miscellaneous XIII Country specific power cord Change report PRIMERGY Server February 2014 ...

Страница 2: ...o take Go through the configurator by following the lines from the top to the bottom Section III Memory example There are X memory slots which can be equipped with XXX MB It is permissible to make up to X passes through the memory upgrade options S26361 XXX XXX S26361 XXX XXX Memory XXX MB Memory XXX MB X times max X times per system max X times per system In one chapter you can only select as man...

Страница 3: ...ATA LFF HDD Option B support for 2x 3 5 SAS SATA HDD hot plug support for SL 0 5 DVD Drive LSD Local Service Display Extension slots MtK DVD sl 4x SAS SATA LFF HDD Option C support for 4x 3 5 SAS SATA HDD hot plug SAS Controller VII support for SL 0 5 DVD Drive Disk Array VIII Communication Network IX Miscellaneous X Hard disk drives VI Slot 6 PCIe 3 x16 170 mm CPU2 this slot is only available wit...

Страница 4: ...Box Option D support for 8x 2 5 SFF SAS SATA HDD hot plug Extension slots occupies two 5 25 bays SAS Controller VII Disk Array VIII Communication Network IX Miscellaneous X Hard disk drives VI Slot 6 PCIe 3 x16 170 mm CPU2 this slot is only available with 2 CPUs implemented Slot5 PCIe 3 x4 280 mm CPU1 Possibility to install PCIe x8 cards 1st pref RAID Slot Slot 4 PCIe 3 x16 280 mm CPU1 Slot 3 PCIe...

Страница 5: ...ows Server 2008 Enterprise Windows Server 2008 Remote Desktop Services Device CAL Windows Server 2008 Standard Windows Server 2008 Remote Desktop Services User CAL Microsoft Windows Server 2008 Client Access Licenses Windows Server 2008 Device CAL Windows Server 2008 User CAL Windows Server 2008 Remote Desktop Services Device CAL Linux Software Windows Server 2008 Remote Desktop Services User CAL ...

Страница 6: ...andard as soon as available Windows Web Server 2008 R2 Windows Small Business Server 2011 Standard I Premium Device CAL Windows Small Business Server 2011 Standard I Premium User CAL Windows Server 2008 Enterprise Windows Server 2008 Remote Desktop Services Device CAL Windows Server 2008 Standard Windows Server 2008 Remote Desktop Services User CAL Microsoft Windows Server 2008 Client Access Licen...

Страница 7: ...y one module has to be selected for an orderable basic unit per CPU Memory upgrade is possible module wise for the Independent Channel Mode or for the Performance Mode Memory mirrroring is supported with 2 identical modules in channel B C CPU 1 or E F CPU 2 Hot Spare Memory is supported with 3 identical modules in channel A B C CPU 1 or D E F CPU 2 SDDC Chipkill is supported only for registered me...

Страница 8: ...lar or onboard controllers SFF Base Unit standard S26361 K1404 V301 SFF Base Unit standard S26361 K1404 V701 3 std fans and std PSU 3 std fans and std PSU 8 port SAS backplane for 8x 2 5 hot plug SAS 8 port SAS backplane for 8x 2 5 hot plug SAS or SATA HD s incl cables for connection to the or SATA HD s incl cables for connection to the modular or onboard controllers modular or onboard controllers...

Страница 9: ...l racks for symmetrical racks PRIMECENTER S2 or M1 M1 or 3rd party racks S26361 F2735 L82 1 bracket PC Rack asym Fujitsu racks Cable management arm for 2U Server 1x per system 1x per system or higher for loose delivery can only be mounted at RMK with CMA adapter for loose delivery SNP SY F1647E301 P Installation ex works for one server or subsystem Hereby the rack will be delivered Rack mounting e...

Страница 10: ...system Max two CPU s can be selected per basic unit Note Max DDR3 Bus Speed depends on One of following CPU s has to be selected as first CPU max DDR3 Bus Speed from the CPU and for an orderable basic unit max DDR3 Memory Speed and Optional second CPU has to be the same type like the first CPU max memory modules on one memory channel Basic 4C CPU s 1x 64 bit Intel Xeon 10MB shared TLC Third Level ...

Страница 11: ... same interface frequency but individual channels may run at different DIMM timings RAS latency CAS latency and so forth No mix of registered and unbuffered modules allowed 2 Rank Sparing Mode configuration Within a memory channel one rank is a spare of the other ranks The Spare Rank is held in reserve and is not available as system memory For the effective memory capacity please refer to the spre...

Страница 12: ...n active data the remain two modules contain mirrored data Supported for RDIMM only Multiple of 2 identical modules to be configured per CPU 1R 2R 1R 2R na na na na na na na Minimum one memory module or order code per CPU first memory Note 1 Unbuffered Memory UDIMM no SDDC chipkill support Max DDR3 memory speed depends on the memory configuration one DDR3 unbuffered ECC mem Module 1 35V No of mem ...

Страница 13: ...x4GB with one CPU Max Memory per CPU 4 6 Modules CPU 6x4GB 6x16GB with one CPU Max Memory per System 8 12 Modules System 48GB 96GB if second CPU is configured Memory Speed Max DDR3 memory speed depends on the memory configuration on one memory channel and the speed of the CPU The memory channel with the lowest speed defines the speed of all CPU channels in the system Voltage setting BIOS DPC DPC D...

Страница 14: ...U or channel E F 2nd CPU 50 of the capacity is used for the mirror the available memory for applications is only half of the installed memory If this mode is used a multiple of 2 identical modules has to be ordered 3 Performance Channel Mode required required if 2nd CPU is configured Bank I Data Data Data Data Data Data optional same type in Bank per CPU black sockets Bank II Data Data Data Data D...

Страница 15: ...Data Data Data Data optional same type in Channel per CPU Rank Sparing Mode requires identical modules same capacity and technology within the same channel The available memory for applications will vary depending on configuration Please refer to the spreadsheet above Effective Memory capacity with active Rank Sparing Mode Population rule for Rank sparing mode is to achieve max available memory 1 ...

Страница 16: ... two 5 25 x 1 6 bays Occupies all 5 25 x 1 6 bays Offers bays for in the accessible bay area in the accessible bay area 1x Local Sv Display option Offers bays for Offers bays for 1x 0 5 5 25 SATA DVD 1x Local Sv Display option 1x 0 5 5 25 SATA DVD max 1x per system 1x 0 5 5 25 SATA DVD 4x 3 5 SAS SATA HDD s 2x 3 5 SAS SATA HDD s Two 1 3 25 satin black bezels One 0 5 3 5 satin black bezel for SAS H...

Страница 17: ...bezel S26361 F3750 L324 with USB3 0 cable for adapter card max 1x per system The USB3 0 Adapter card or the USB2 0 cable set S26361 F3750 L20 must be ordered with the drive additional RDX cartridges can be ordered S26361 F3750 E504 RDX 320GB S26361 F3857 L320 RDX 500 5 25 RDX 500GB S26361 F3857 L500 100MB s USB 3 0 RDX 1TB S26361 F3857 L600 Connector USB 3 0 B 10x RDX320 S26361 F3857 L329 with USB...

Страница 18: ...rium SAS Tape drive LTO6HH Ultrium SAS 400GB 60MB s SAS 3Gb 800GB 120MB s SAS 6Gb 1500GB 140MB s SAS 6Gb 2500GB 160MB s SAS 6Gb 1x Connector mini SAS Connector mini SAS Connector mini SAS Connector mini SAS incl SAS cable incl SAS cable incl SAS cable incl SAS cable incl cleaning cartridge incl cleaning cartridge incl cleaning cartridge incl cleaning cartridge without data cartridge without data c...

Страница 19: ...volume Hot replace is only possible running RAID S26361 F4005 E530 S26361 F4005 E545 S26361 F4005 E560 HD 300GB 15krpm 3 5 HD 450GB 15krpm 3 5 HD 600GB 15krpm 3 5 15 000rpm 4ms 16MB Cache 15 000rpm 4ms 16MB Cache 15 000rpm 4ms 16MB Cache SAS 6Gb s SAS 6Gb s SAS 6Gb s hot plug hot replace tray hot plug hot replace tray hot plug hot replace tray max 8x per system max 8x per system max 8x per system ...

Страница 20: ... 1x per system see Section VIII S26361 F2826 E140 For a later configuration of more than 4 SATA HDDs the trigger is not necessary Trigger to request a PCI SAS Controller In this case it is sufficient to implement a SAS controller for configuring more than 4 SATA HDDs It is not allowed to connect the SATA HDDs to different controllers max 1x per system In case of running more than 4 HDDs all of the...

Страница 21: ...5 HD 300GB 15krpm 2 5 15000rpm 4 5ms 32MB Cache 15000rpm 4 5ms 32MB Cache SAS 6Gb s SAS 6Gb s hot plug hot replace tray hot plug hot replace tray 8x max 8 16x per system max 8 16x per system 16x S26361 F5247 E130 S26361 F5247 E145 S26361 F5247 E160 HD 300GB 10krpm 2 5 HD 450GB 10krpm 2 5 HD 600GB 10krpm 2 5 10000rpm 4 5ms 32MB Cache 10000rpm 4 5ms 32MB Cache 10000rpm 4 5ms 32MB Cache SAS 6Gb s SAS...

Страница 22: ...orm factor PCIe 3 0 x8 MD2 form factor full height bracket full height bracket full height bracket max 2x per system max 1 per system max 1 per system S26361 F3257 E216 S26361 F3669 E125 Cache Battery Backup Unit Flash Backup Unit with 16cm cable set with 25cm cable set max 1x per Controller max 1x per Controller as soon as available Advanced Software Option S26361 F3669 E661 as soon as available ...

Страница 23: ... with ECC 1GB Cache with ECC max 3x RAID 0 1 1E RAID 0 1 10 5 50 6 60 RAID 0 1 10 5 50 6 60 RAID 0 1 10 5 50 6 60 RAID ctrl Sup for 3Gb s and 6Gb s optional BBU optional FBU optional FBU int and ext SATA and SAS HDs Support for 3Gb s and 6Gb s Support for 3Gb s and 6Gb s Support for 3Gb s and 6Gb s in total PCIe x8 SATA and SAS hard drives SATA and SAS hard drives SATA and SAS hard drives Low prof...

Страница 24: ...t 1 channel 8GBit sec FC Controller 2 channel 8GBit sec FC Controller LC Interface for 50µm Fiber LC Interface for 50µm Fiber PCIe x8 170mm PCIe x8 170mm max 2x per system max 2x per system 2x S26361 F3961 E1 S26361 F3961 E2 8GBit s FC Controller 8GBit s FC Controller Emulex Emulex LPe1250 full height bracket LPe12002 full height bracket 1 channel 8GBit sec FC Controller 2 channel 8GBit sec FC Con...

Страница 25: ...el I350 T2 Eth Ctrl 2x1Gbit Cu PCIe x4 D3035 Eth Ctrl 2x1Gbit PCIe x4 D2735 2 Cu Intel Powerville based 2 port Server Adapter Intel Powerville based 2 port Server Adapter Intel Kawela based 2 port Server Adapter PCIe x4 Low Profile PCIe x4 Low Profile PCIe x4 Low Profile full height FH bracket full height FH bracket full height FH bracket ext for RJ45 plug Cat 5 ext for RJ45 plug Cat 5 ext for RJ4...

Страница 26: ...ustomized twinax cable for customized twinax cable for customized twinax cable for cabling view full rack setup ex factory full rack setup ex factory full rack setup ex factory cable length is selected by cable length is selected by cable length is selected by requirement in the factory requirement in the factory requirement in the factory Fujitsu branded cable Brocade branded cable Cisco branded ...

Страница 27: ...America For Shipments to Asia pacific For Shipments to Japan regions For Shipments to America EMEA or India regions 1x per system 1x per system 1x per system A power cord has to be ordered once per basic unit and additional a second power cord if an additional hot plug redundant power supply modul is ordered Power cord options 1x per PSU Power cord options 1x per PSU 1 8m grey T26139 Y1740 E10 D A...

Страница 28: ...added 2013 03 25 S26361 F3669 E661 L661 RAID advanced SW options added for RAID Ctrl SAS 6G 8port external 2013 03 18 S26361 F3750 E324 504 E604 RDX Cartridge bundles added 2012 12 13 S26361 F3641 E4 BD slim with frame included again 2013 01 08 S26361 F5228 E100 New 2 5 BC SAS 7 2K HDD 2013 01 08 S26361 F5247 E130 New 2 5 SAS 10K HDD mix with BC SATA supported sucessor for F5227 2012 12 13 S26361 ...

Отзывы: