TX200 S6
Options Guide
103
Conversion from a floorstand model to a rack model
Ê
Push the right-hand side cover in the direction of the arrow.
Ê
Lift off the right-hand side cover.
I
The right-hand side cover is no longer required.
Ê
Lay the server on its right-hand side.
V
CAUTION!
Get a second person to help you do this. The server can weigh up to
35 kg.
Figure 86: Removing the foot mounting rail
Ê
Loosen the three screws (1) of the foot mounting rail.
Ê
Slide the foot mounting rail backward (2) until the hooks disengage.
Ê
Take off the foot mounting rail.
I
The foot mounting rail is no longer required.
The drive cage for the accessible drives is constructed in such a way that the
accessible drives and the front panel module can be taken out simply, turned
through 90° to the left, and then be reinstalled.
Ê
Remove the dummy covers from the drive cage (
figure 22 on page 54
).
Ê
Unplug the cables from the system board or the accessible drives and
remove the drives from the drive cage.
Ԙ
Ԙ
Ԙ
ԙ
Содержание PRIMERGY TX200 S6
Страница 1: ...Options Guide English PRIMERGY TX200 S6 Server Options Guide Edition November 2011 ...
Страница 6: ...OptionsGuide TX200 S6 ...
Страница 10: ...OptionsGuide TX200 S6 Contents ...
Страница 16: ...16 OptionsGuide TX200 S6 Introduction ...
Страница 36: ...36 OptionsGuide TX200 S6 Preparation ...
Страница 40: ...40 OptionsGuide TX200 S6 Main memory ...
Страница 86: ...86 OptionsGuide TX200 S6 Expansion cards and BBU ...
Страница 114: ...114 OptionsGuide TX200 S6 Completion ...
Страница 115: ...TX200 S6 Options Guide 115 13 Appendix 13 1 Cabling You will find suggestions for cabling on the next pages ...
Страница 122: ...122 OptionsGuide TX200 S6 Appendix ...
Страница 124: ...124 OptionsGuide TX200 S6 Index ...