TX200 S6
Operating Manual
47
Hardware installation
4.2
Setting up the floorstand model
I
If you are not installing a PRIMERGY TX200 S6 floorstand model, skip
this section and continue reading at
section "Installing/removing the rack
model" on page 49
.
V
CAUTION!
Follow the safety instructions in
chapter "Important information" on
page 31
.
Ê
Transport the server to the place where you want to set it up.
Ê
Unpack the server (see
section "Unpacking the server" on page 46
).
Ê
Set up the server.
Note that for safety reasons (danger of tipping) the anti-tilt bracket must be
mounted on the back of the server (see section
"Mounting the anti-tilt
bracket" on page 48
).
V
CAUTION!
–
The device must be protected from direct sunlight.
–
The essential minimum clearance for servicing must be
maintained (see
"Maintenance area for the floorstand model" on
page 27
).
–
Access to the rear of the server must be assured so that other
devices (e.g. memory subsystems) can be connected.
–
A clearance of at least 200 mm must be maintained in front of and
behind the system to ensure proper ventilation.
–
The mains plug must be accessible easily and safely.
Ê
Wire the server. Read the information in
section "Connecting devices to the
server" on page 59
and
section "Notes on connecting/disconnecting cables"
on page 63
.
Ê
Connect the system to the mains (see
section "Connecting the server to the
mains" on page 60
).
Содержание PRIMERGY TX200 S6
Страница 1: ...Operating Manual English PRIMERGY TX200 S6 Server Operating Manual Edition July 2010 ...
Страница 6: ...Operating Manual TX200 S6 ...
Страница 51: ...TX200 S6 Operating Manual 51 Hardware installation Figure 3 Mechanical requirements 735 770 mm 100 mm 1 6mm ...
Страница 64: ...64 Operating Manual TX200 S6 Hardware installation ...
Страница 84: ...84 Operating Manual TX200 S6 Property and data protection ...
Страница 90: ......
Страница 120: ...120 Operating Manual TX200 S6 Appendix server specification ...
Страница 126: ......