RX600 S6
Service Supplement
29
Replacement routines
4.7
Replacing the control panel
Ê
Open the server as described in
section "Opening the server" on page 21
.
Ê
Remove the following components:
– all of the fans (for a description see the Operating Manual)
– all memory boards and memory dividers (for a description see the
Options Guide)
I
Make a note about the slot from which you pulled each memory
board for you have to replace it back into the same slot.
Ê
Remove the fan box (see
page 27
).
Ê
Unplug the cable from the back of the control panel.
Figure 11: Removing the control panel
Ê
Press on the plastic tabs (1) on both sides of the control panel and push it
outward (2).
To install the control panel follow the above steps in reverse.
/
/