86
Upgrade and Maintenance Manual
RX4770
M1
Basic software procedures
Using the ID button on the front panel
Ê
Press the ID button on the front panel to switch off the ID indicators.
Using the iRMC web frontend
Ê
Enter the ServerView iRMC web frontend.
Ê
Under
System Overview
, click
Identify LED Off
to switch off the ID indicators.
Using ServerView Operations Manager
Ê
In ServerView Operations Manager
Single System View
and press the
Locate
button in the title bar to switch off the ID indicator.
5.2.19 Performing a fan test after replacing a defective fan
After replacing a defective system fan or power supply unit containing a
defective fan, the fan error indicators will stay lit until the next fan test. By
default, a fan test is automatically started every 24 hours. The first automatic fan
test being performed after replacing a fan will turn off the fan error indicator.
If you want to start the fan test manually, you can do so by following the
description below:
Executing the fan test via the iRMC Web interface
Ê
Log into the iRMC web interface.
Ê
Under
Sensors
select
Fans
.
Ê
Select the replaced fan in the system fans group and click
Start Fan Test
.
I
For detailed information on iRMC settings, refer to the "Integrated
Remote Management Controller" user guide.
Executing the fan test via ServerView Operations Manager
Ê
Open the ServerView Operations Manager and log in.
Ê
Under
Administration
select
Server Configuration
.
Ê
In the hierarchy tree of the
Server list
tab, select the server to be configured.
Ê
In the right-hand side of the window, specify the details on the selected
server and confirm your entries by clicking
GO...
.
Содержание Primergy RX4770 M1
Страница 18: ...18 Upgrade and Maintenance Manual RX4770 M1 Contents ...
Страница 88: ...88 Upgrade and Maintenance Manual RX4770 M1 Basic software procedures ...
Страница 122: ...122 Upgrade and Maintenance Manual RX4770 M1 Hard disk drives solid state drives ...
Страница 200: ...200 Upgrade and Maintenance Manual RX4770 M1 Expansion cards and backup units ...
Страница 243: ...RX4770 M1 Upgrade and Maintenance Manual 243 Processors Figure 146 Opening the load plate B Ê Fully open the load plate ...
Страница 258: ...258 Upgrade and Maintenance Manual RX4770 M1 Processors ...
Страница 310: ...310 Upgrade and Maintenance Manual RX4770 M1 System board and components ...
Страница 314: ...314 Upgrade and Maintenance Manual RX4770 M1 Cables ...
Страница 332: ...332 Upgrade and Maintenance Manual RX4770 M1 Appendix ...