112
Upgrade and Maintenance Manual
RX4770
M1
Hard disk drives / solid state drives
7.3
Removing 2.5-inch HDD / SSD / PCIe SSD
modules
I
The preliminary and concluding steps are only necessary for HDD / SSD
modules not for PCIe SSD modules. PCIe SSD modules are never
combined in a RAID array.
7.3.1
Preliminary steps
Ê
If the HDD / SSD module to be removed is combined into a RAID array,
please proceed as follows:
Customer Replaceable Unit
(CRU)
Hardware: 5 minutes
Tools:
tool-less
RAID level
Procedure
RAID 0
Only remove an HDD module combined in a RAID 0 array if
defective.
V
CAUTION!
Removing an operational HDD module will result
in data loss!
RAID 1
RAID 5
Removing an HDD module from a RAID 1 or RAID 5 array
will not result in data loss.
However, the removed drive needs to be replaced
immediately by an HDD module of the same or larger
capacity.
I
After replacing the HDD module, RAID rebuild will
be performed as a background process as
described in section
"Performing a RAID array
rebuild" on page 81
.
Содержание Primergy RX4770 M1
Страница 18: ...18 Upgrade and Maintenance Manual RX4770 M1 Contents ...
Страница 88: ...88 Upgrade and Maintenance Manual RX4770 M1 Basic software procedures ...
Страница 122: ...122 Upgrade and Maintenance Manual RX4770 M1 Hard disk drives solid state drives ...
Страница 200: ...200 Upgrade and Maintenance Manual RX4770 M1 Expansion cards and backup units ...
Страница 243: ...RX4770 M1 Upgrade and Maintenance Manual 243 Processors Figure 146 Opening the load plate B Ê Fully open the load plate ...
Страница 258: ...258 Upgrade and Maintenance Manual RX4770 M1 Processors ...
Страница 310: ...310 Upgrade and Maintenance Manual RX4770 M1 System board and components ...
Страница 314: ...314 Upgrade and Maintenance Manual RX4770 M1 Cables ...
Страница 332: ...332 Upgrade and Maintenance Manual RX4770 M1 Appendix ...