148
Upgrade and Maintenance Manual
TX300 S8 / RX350 S8
Basic software procedures
Ê
Select the
Advanced
menu.
Ê
Under
Memory Status
verify that none of the memory modules are marked as
Failed
.
Ê
Save your changes (if applicable) and exit the BIOS.
I
For detailed information on how to access the BIOS and modify settings,
refer to your server’s "BIOS Setup Utility" reference manual.
5.2.12 Verifying the system time settings
I
This task only applies to Linux environments.
After the system board has been replaced, the system time is set automatically.
By default, the RTC (Real Time Clock) time standard is set as the local time.
If a Linux OS is used and the hardware clock has been configured as UTC
(Universal Time, Coordinated) in the operating system, the BMC local time may
not be mapped correctly.
Ê
After replacing the system board, ask the system administrator whether the
RTC or UTC time standard is to be used as system time.
I
If the system time (RTC) is set to UTC, the SEL (System Event Log)
time stamps may differ from the local time.
Ê
Enter the BIOS.
Ê
Select the
Main
menu.
Ê
Under
System Time
and
System Date
specify the correct time and date.
I
By default, the system time set in the BIOS is RTC (Real Time Clock)
local time. If your IT infrastructure relies on universally accepted time
standards, set the
System Time
to UTC (Universal Time, Coordinated)
instead. Greenwich Mean Time (GMT) can be considered equivalent
to UTC.
Ê
Save your changes and exit the BIOS.
I
For detailed information on how to access the BIOS and modify settings,
refer to your server’s "BIOS Setup Utility" reference manual
Содержание PRIMERGY RX350 S8
Страница 6: ...Upgrade and Maintenance Manual TX300 S8 RX350 S8 ...
Страница 44: ...44 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Before you start ...
Страница 160: ...160 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Basic software procedures ...
Страница 182: ...182 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Power supply ...
Страница 320: ...320 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Hard disk drives solid state drives ...
Страница 344: ...344 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Fans ...
Страница 484: ...484 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Main memory ...
Страница 528: ...528 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Processors ...
Страница 644: ...644 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Front panel and external connectors ...
Страница 734: ...734 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Converting a tower server to a rack server ...
Страница 792: ...792 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Appendix ...