142
Upgrade and Maintenance Manual
TX300 S8 / RX350 S8
Basic software procedures
5.2.7
Resetting the error status after replacing memory
modules or processors
5.2.7.1
Memory modules
ServerView Operations Manager may report a defective memory module in
case of a memory error.
I
Important note
After replacing a defective memory module, please check if the error
counter has been reset automatically. If the memory slot is still marked
as failed, please reset the error counter manually using one of the
methods below.
Using the iRMC web frontend
Ê
Enter the ServerView iRMC web frontend.
Ê
Select the
System Information
menu.
Ê
Under
System Components
, select the check boxes next to the affected
memory modules.
Ê
From the drop down list, select
Reset Error Counter
.
Ê
Click
Apply
for the changes to take effect.
Using ServerView Maintenance Tools (Windows only)
Ê
Launch the ServerView Maintenance Tools:
– Windows Server 2008 R2 and below:
Start
>
(All) Programs
>
Fujitsu
>
ServerView Suite
>
Agents
>
Maintenance Tools
– Windows Server 2012 and above:
Start
>
Apps
>
Fujitsu
>
Maintenance Tools
Ê
Choose the
Memory
status tab.
Ê
Select the memory module which shows the pre-failure status.
Ê
Click on
Reset Status
.
I
The
Reset Status
button will only be available if the selected memory
module contains errors.
Содержание PRIMERGY RX350 S8
Страница 6: ...Upgrade and Maintenance Manual TX300 S8 RX350 S8 ...
Страница 44: ...44 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Before you start ...
Страница 160: ...160 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Basic software procedures ...
Страница 182: ...182 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Power supply ...
Страница 320: ...320 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Hard disk drives solid state drives ...
Страница 344: ...344 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Fans ...
Страница 484: ...484 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Main memory ...
Страница 528: ...528 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Processors ...
Страница 644: ...644 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Front panel and external connectors ...
Страница 734: ...734 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Converting a tower server to a rack server ...
Страница 792: ...792 Upgrade and Maintenance Manual TX300 S8 RX350 S8 Appendix ...