Operating manual
RX300
S5
Installing/removing the server in/from the rack
Hardware installation
4.2.3
Installation in 3rd party racks
I
The support systems from Fujitsu Technology Solutions are suitable for
use in any 3rd party racks for standard servers (installation depth 735 -
770 mm without restrictions.
Ê
Refer to the manual from the rack manufacturer for details of the mechanical
installation and the climatic conditions.
V
CAUTION!
When installing in 3rd party racks, it must be ensured that an air flow
from the front to the back of the rack is guaranteed.
Ê
Fit the required original parts (support bracket or cable management
system).
I
Under certain circumstances, you will not be able to use some of the
parts from the rack installation kit supplied - you will need to use
original 3rd party rack parts instead.
Ê
Remove the outer telescopic rail as described in
page 48
(
figure 8
).
Inserting the server
The support systems can be used for installation depths of
735 - 770
mm. The
spring element of the support system enables the length to be adjusted as
required.
Ê
Secure the support systems as described in section
"Installing the support
systems" on page 49
.
Ê
Mount the server (see
"Preparing the server" on page 50
) and route the
cables as described in the original manual of the rack..
V
CAUTION!
Ensure that the safety lock has been inserted
before
the server is
inserted (see
figure 9 on page 49
).