RX2540 M1
Upgrade and Maintenance Manual
429
Appendix
1
Global Error indicator (yellow) on the system board, visible through
the chassis perforation.
–
Lights up yellow
if a prefailure event has been detected that
requires (precautionary) service intervention.
–
Flashes yellow
if an error was detected that requires service
intervention.
–
Does not light up
if there is no critical event.
If the event is still acute after a power cycle, the indicator is
activated after the restart.
The indicator also lights up in standby mode.
You can find more details on the indicated errors in the System
Event Log (SEL), in the ServerView Operations Manager or via the
iRMC S4's Web interface.
ID indicator (blue) on the system board, visible through the chassis
perforation.
Lights up blue when the system has been selected by pressing the
ID button. To deactivate, press the button again.
The ID indicator can also be activated via the ServerView
Operations Manager and the iRMC S4 Web interface and its status
reported to the ServerView Operations Manager and to the
iRMC S4.
2
CSS indicator (yellow)
–
Lights up yellow
if a prefailure event was detected for a CSS
component that you can fix yourself (for reasons of precaution)
with the CSS concept.
–
Flashes yellow
if an error was detected that you can fix
yourself with the CSS concept.
–
Does not light up
when the system is OK.
If the event is still acute after a power cycle, the indicator is
activated after the restart.
Содержание PRIMERGY RX2540 M1
Страница 24: ...24 Upgrade and Maintenance Manual RX2540 M1 Contents ...
Страница 38: ...38 Upgrade and Maintenance Manual RX2540 M1 Before you start ...
Страница 68: ...68 Upgrade and Maintenance Manual RX2540 M1 Basic hardware procedures ...
Страница 150: ...150 Upgrade and Maintenance Manual RX2540 M1 Hard disk drives solid state drives ...
Страница 158: ...158 Upgrade and Maintenance Manual RX2540 M1 System fan ...
Страница 316: ...316 Upgrade and Maintenance Manual RX2540 M1 Processors ...
Страница 330: ...330 Upgrade and Maintenance Manual RX2540 M1 Accessible drives ...
Страница 362: ...362 Upgrade and Maintenance Manual RX2540 M1 Front panel and external front connectors ...
Страница 400: ...400 Upgrade and Maintenance Manual RX2540 M1 System board and components Ê Removing the fan box on page 154 ...
Страница 410: ...410 Upgrade and Maintenance Manual RX2540 M1 System board and components ...
Страница 418: ...418 Upgrade and Maintenance Manual RX2540 M1 Cables ...
Страница 438: ...438 Upgrade and Maintenance Manual RX2540 M1 Appendix ...