
Jumper
Status
Description
JWD1
Watch Dog
Default
NMI
Disabled
14.4
Minimum startup configuration
Field Replaceable Units
(FRU)
If the server does not start up or other problems occur, it may be necessary to
take the system down to its most basic configuration in order to isolate the
defective component.
The minimum startup configuration consists of the following components and
cables:
Component
Notes
System board
no TPM or expansion cards installed
2 CPU with CPU heat
sink
1 memory module
installed in DIMM slot A2
Front panel module
1 PSU
installed in PSU bay PSU 1
Table 4: Minimum startup configuration - components
Cable
Notes
Front panel cable
Power cable
Table 5: Minimum startup configuration - cables
Appendix A
216
Upgrade and Maintenance Manual
RX2450 M1
Содержание PRIMERGY RX2450 M1
Страница 14: ...Content Upgrade and Maintenance Manual RX2450 M1 ...
Страница 82: ...Power supply unit PSU 82 Upgrade and Maintenance Manual RX2450 M1 ...
Страница 156: ...Expansion cards and riser cards 156 Upgrade and Maintenance Manual RX2450 M1 ...
Страница 166: ...Main memory 166 Upgrade and Maintenance Manual RX2450 M1 ...
Страница 168: ...11 2 Basic information CPU 1 CPU 2 Figure 133 CPU slots Processor CPU 168 Upgrade and Maintenance Manual RX2450 M1 ...
Страница 190: ... Switching on the server on page 49 Front panel 190 Upgrade and Maintenance Manual RX2450 M1 ...
Страница 218: ...Appendix A 218 Upgrade and Maintenance Manual RX2450 M1 ...
Страница 222: ......