
▶
"Shutting down the server" on page 37
.
▶
"Disconnecting the power cord (AC PSU)" on page 38
▶
"Getting access to the component" on page 39
Replacing the defective CMOS battery
1
2
3
4
Figure 156: Replacing the CMOS battery
▶
Press the locking spring into direction of the arrow (1), so that the CMOS
battery jumps out of its socket.
▶
Remove the CMOS battery (2).
CAUTION
Sharp tools such as screw drivers might damage system board
components in case of slipping.
▶
If the CMOS battery cannot be ejected without the help of a tool,
it is recommended to use a tooth pick.
▶
Insert a new CMOS battery of the same type into the socket (3) and (4).
Concluding steps
▶
Dispose of the CMOS battery in accordance with local regulations
concerning special waste.
▶
▶
"Connecting the power cord" on page 48
System board and components
RX2450 M1
Upgrade and Maintenance Manual
193
Содержание PRIMERGY RX2450 M1
Страница 14: ...Content Upgrade and Maintenance Manual RX2450 M1 ...
Страница 82: ...Power supply unit PSU 82 Upgrade and Maintenance Manual RX2450 M1 ...
Страница 156: ...Expansion cards and riser cards 156 Upgrade and Maintenance Manual RX2450 M1 ...
Страница 166: ...Main memory 166 Upgrade and Maintenance Manual RX2450 M1 ...
Страница 168: ...11 2 Basic information CPU 1 CPU 2 Figure 133 CPU slots Processor CPU 168 Upgrade and Maintenance Manual RX2450 M1 ...
Страница 190: ... Switching on the server on page 49 Front panel 190 Upgrade and Maintenance Manual RX2450 M1 ...
Страница 218: ...Appendix A 218 Upgrade and Maintenance Manual RX2450 M1 ...
Страница 222: ......