42
Upgrade and Maintenance Manual
CX400 M4
Basic hardware procedures
4.4
Extending/removing the server enclosure
out of the rack
V
CAUTION!
●
Use the anti-tilt plate to prevent the rack from tipping when installing
the rack. Pulling the server out of the rack without having installed the
anti-tilt plate may cause the rack to tip over.
●
Be careful not to pinch fingers or clothes when sliding out the server
enclosure or pushing it back. Failure to do so may cause injury.
●
For further safety information, please refer to chapter
.
I
In most cases maintenance tasks can be performed while the server
is extended from the rack. However, depending on accessibility or
security guidelines, it may make sense to completely remove the
server from the rack cabinet for maintenance purposes.
4.4.1
Preliminary steps
Ê
"Shutting down the server node" on page 40
Ê
"Disconnecting the power cord" on page 41
Ê
If applicable, disconnect all external cables.
Ê
If you remove the CX400 M4 server enclosure out of the rack, remove all
server nodes, PSUs, HDDS/SSDs from the server enclosure, see sections
"Removing server nodes from the server enclosure" on page 46
and
Содержание PRIMERGY CX400 M4
Страница 6: ...Upgrade and Maintenance Manual CX400 M4 ...
Страница 126: ...126 Upgrade and Maintenance Manual CX400 M4 Hard disk drives HDD solid state drives SSD and 2 5 inch PCIe SSD ...
Страница 156: ...156 Upgrade and Maintenance Manual CX400 M4 Midplane kit ...
Страница 176: ...176 Upgrade and Maintenance Manual CX400 M4 Front panel ...
Страница 178: ...178 Upgrade and Maintenance Manual CX400 M4 Cabling 11 2 Cabling Figure 100 Cabling 1 Front panel 2 Midplane kit ...