96
Upgrade and Maintenance Manual
CX400 M4
Hard disk drives (HDD), solid state drives (SSD) and 2.5-inch PCIe-SSD
7.2.2
Removing a 2.5-inch HDD/SSD dummy module
Figure 44: Removing a 2.5-inch HDD/SSD dummy module
I
Dummy modules have been installed into unused HDD/SSD bays.
Before installing an additional HDD/SSD, the dummy module needs to
be removed from the desired drive bay.
Ê
Press in on the locking clips of the dummy module to disengage the locking
mechanism.
Ê
While keeping the locking clip pressed, pull the dummy module out of its bay.
V
CAUTION!
Save the dummy module for future use.
Always replace dummy modules into unused HDD/SSD bays to comply
with applicable EMC regulations and satisfy cooling requirements.