BX924 S4
Upgrade and Maintenance Manual
117
Hard disk drives / Solid state drives
Ê
If applicable, remove the mezzanine carrier as described in chapter
"Mezzanine cards" on page 121
.
Ê
Remove the respective disk mounting kit from the mounting platform as
described in section
"Removing HDD/SSD" on page 108
.
V
CAUTION!
Ensure that the drives are uniquely identified so that you can reinsert
them into their original locations after replacing the backplane.
Ê
Remove the 4 screws from the mounting frame as described in section
"Removing SSD 0" on page 109
or
"Removing HDD/SSD 1" on page 111
.
Ê
Remove the HDD/SSD from the mounting frame as described in section
"Removing SSD 0" on page 109
or
"Removing HDD/SSD 1" on page 111
.
6.6.3
Removing the SAS / PCH backplane
Figure 30: Removing the SAS / PCH backplane
Ê
Loosen the two screws (see arrows) of the defective SAS / PCH backplane.
Ê
Remove the defective SAS / PCH backplane from the mounting frame.