CHAPTER 7 PRIMEPOWER600 Pedestal Server
7.2.2
Control panel
The PRIMEPOWER600 Pedestal Server is provided with the control panel shown in Figure 7.3 .
REQUEST RESET
AUTO
MANUAL
(3) REQUEST Switch
SECURE
CHECK
POWER
(1) RESET Switch
(2) MODE Switch
(6) CHECK LED (Amber )
(7) POWER LED (Green)
(5) POWER Switch
(4) LCD Panel
Figure 7.3
Control Panel
Note:
To prevent erroneous operation, all push-button switches on the control panel are designed not to
function unless held down for at least 0.3 seconds.
(1) RESET switch (push button)
CAUTION
Data Destruction
Pressing the RESET switch while the system is running may cause
data to be lost.
The RESET switch is used to reset the system to its initial state and is enabled or disabled by the
MODE switch described in "(2) MODE switch".
(2) MODE switch (3-position slider)
CAUTION
Data Destruction
Install the "Enhanced Support Facility" before using the system.
Without this package, a front panel-miss operation or hardware
error may cause the system to shutdown or data to be lost.
The MODE switch has three settings and is used to specify the run mode at power on or system
reboot, and to whether the POWER, RESET and REQUEST switches are "enabled" or "disabled".
118
Содержание Primepower200
Страница 1: ...P321 E122 04EN PRIMEPOWER PRIMEPOWER200 PRIMEPOWER400 PRIMEPOWER600 ...
Страница 2: ......
Страница 12: ......
Страница 116: ......
Страница 142: ......
Страница 192: ......
Страница 254: ......
Страница 255: ...12 RCI Commands CONTENTS 12 1 Overview 228 12 2 RCI Commands 228 227 ...
Страница 258: ......
Страница 266: ......
Страница 267: ...14 Glossary CONTENTS 14 1 Glossary 240 239 ...
Страница 272: ......