CHAPTER 6 PRIMEPOWER400 Rackmount (10U) Server
(6) CHECK LED
IMPORTANT
When the PRIMEPOWER400 Rackmount (10U) Server detects an error in the power line
or abnormal temperatures, the CHECK LED blinks and the power is automatically turned
off to prevent unit damage and ensure safety.
The CHECK LED blinks or lights up when the PRIMEPOWER400 Rackmount (10U) Server
detects an error.
When the power is turned on, the CHECK LED lights up and then goes out. This is not an error. If
the CHECK LED stays lit and does not go out at power on, this indicates an error.
When an error occurs, note down the details displayed on the LCD panel, and contact a service
engineer.
(7) POWER LED
The POWER LED indicates the power state of the system. This LED lights up when the power is
on, and goes out when the power is turned off.
6.2.3
Rear side
The names and functions of parts on the rear of the PRIMEPOWER400 Rackmount (10U) Server are as follows.
(1) AC power inputs
(2) PCI slots
(5) RCI port
(4) UPS port
(3) Power control port
(9) 100Base-TX port
(8) Keyboard port
(6) Serial port A
(7) Serial port B
Figure 6.4
Rear of PRIMEPOWER400 Rackmount (10U) Server