Table
4.2
Chassis
Control
Format
Byte
Data
Field
Request
Data
1
[7:4]
reserved
[3:0]
chassis
control
0h
=
Power
down
1h
=
Power
up
2h
=
Power
cycle
(Not
supported)
3h
=
Hard
reset
4h
=
Pulse
Diagnostic
Interrupt
5h
=
Initiate
a
soft-shutdown
6h-Fh
=
reserved
Response
Data 1
Completion
Code
Table
4.3
Chassis
Device
Commands
Command
Synchronization
CMD
Privilege
Target(*1)
Chassis
Node
Get
Chassis
Status
Synchronous
01h
User
Supported
Supported
Chassis
Control
Asynchronous
02h
User
Supported
Supported
-t
<target>
4.1.2
Chassis
Control
(NetFN:00h,
CMD:02h)
Use
the
command
to
power
on/off
nodes.
This
command
only
issues
power-on/off
instructions,
and
the
power-on/off
processing
is
executed
separately.
If
the
destination
is
the
chassis,
"Not
supported"
(Completion
Code:
C1h)
is
the
response.
4.1.3
IPMI
Standard
Command
Table
This
section
shows
a
list
of
IPMI
standard
commands.
*1
Target
for
the
issued
command
How
to
Specify
the
Target
You
can
specify
the
target
with
the
-t
option
in
the
ipmi
command.
Options
you
can
specify
for
the
target
-
0x20
Chassis
-
0x30
Node#0
-
0x32
Node#1
-
0x34
Node#2
-
0x36
Node#3
-
0x38
Node#4
-
0x3a
Node#5
Chapter
4
Command
Support
(IPMI)
C120-0091-02EN
4.1
Command
Tables
55
Содержание PRIMEHPC FX1000
Страница 34: ...Figure 3 3 System Event Logs Screen Chapter 3 Web GUI Functions C120 0091 02EN 3 2 System Event Logs 16 ...
Страница 74: ... 0x3c Node 6 0x3e Node 7 Chapter 4 Command Support IPMI C120 0091 02EN 4 1 Command Tables 56 ...
Страница 98: ...Figure A 18 Display of Certificate Appendix A REMCS C120 0091 02EN A 2 REMCS Detail Setup 80 ...
Страница 100: ...Figure A 20 Replace Connection Center List Appendix A REMCS C120 0091 02EN A 2 REMCS Detail Setup 82 ...
Страница 101: ......