– 19 –
VOLTAGE OF EACH CONNECTOR
1. How to measure the voltages on the Main Power Supply PCB in protect mode.
• Since a voltage is applied to the Main Power PCB and PFC PCB heat sinks while the set is operating,
do not touch the heat sinks.
• After the power cord plug was pulled out, do not pull out the connector on the Main Power PCB until
the Green LED (D531: Discharge check LED) turns off.
1) Disconnect CN4, CN10, CN41, CN42, CN49 and CN50
2) Connect pins 1 and 2, 3 and 4 of CN4.
3) Press the power button.
2. On the Main Power Supply PCB. (M00BV)
CN41
Ground
No.
NAME
SPEC.
1
Vcc 1
5.0V +/- 0.25V
2
9
Vs
180.0V +/- 3.2V
5
CN50
Ground
No.
NAME
SPEC.
3
Va
65.0V +/- 1.3V
4
1
Vw
170.0V +/- 5.0V
2
CN42
Ground
No.
NAME
SPEC.
3
-Vy
-165.0V +/- 3.0V
5
4
Vsc
120.0V +/- 3.5V
3
CN10
Ground
No.
NAME
SPEC.
3
Ve
16.0V +/- 0.4V
4
CN352
Ground
No.
NAME
SPEC.
1
P5V
5.0V +/- 0.25V
4
3
+14V
14.0V +/- 0.7V
4
10
-8V
-8.0V +/- 0.4V
6
CN351
Ground
No.
NAME
SPEC.
3
+2.5V
2.5V +/- 0.13V
2
6
+3.3V
3.3V +/- 0.17V
5
10
+6.5V
6.5V +/- 0.33V
9