TROUBLESHOOTING USING LED AND OSD
1. Display
(1) OSD
Two kinds of error messages are displayed on the screen, and the power is turned off 10 sec later.
(2) LED
LED error is displayed continuously after the power is turned off.
2. Error types and check points
On screen display
Cause
Check point
ERROR MESSAGE CONDITION 1
Fan protector operated
• Fan
• AC/DC power unit
• DC/DC power PCB
• Main/Digital PCB
ERROR MESSAGE CONDITION 2
Temperature protector
operated
• Ambient temperature of unit
• Main/Digital PCB
• Temp. sensor PCB
(1) OSD
LED lamp display status
Cause
Check point
Steady light (Red)
Stand-by status
–––––––––––
Continuous
Flashes continuously (Red)
No power
Power supply protector
operated
• AC/DC power unit
• DC/DC power PCB
• PDP panel
1 time
Flashes once in 3 sec. (Red)
Fan protector operated
• Fan
• AC/DC power unit
• DC/DC power PCB
• Main/Digital PCB
2 times
Flashes twice in 3 sec. (Red)
Temperature protector
operated
• Ambient temperature of unit
• Signal PCB
• Temperature sensor PCB
4 times
Flashes four times in 3 sec. (Red)
Main/Digital circuit faulty
• Main/Digital PCB
5 times
Flashes five times in 3 sec. (Red)
Video circuit faulty
• Video PCB Assy