![Fujitsu MPG3102AT Скачать руководство пользователя страница 181](http://html.mh-extra.com/html/fujitsu/mpg3102at/mpg3102at_product-manual_121591181.webp)
6 - 4
C141-E110-03EN
6.1.3
Response to software reset
The master device does not check the DASP- signal for a software reset. If a slave device is
present, the master device checks the PDIAG- signal for up to 31 seconds to see if the slave device
has completed the self-diagnosis successfully.
After the slave device receives the software reset, the slave device shall report its presence and the
result of the self-diagnostics to the master device as described below:
PDIAG- signal: negated within 1 ms and asserted within 30 seconds then negated within 31
seconds.
When the IDD is set to a slave device, the IDD asserts the DASP- signal when negating the
PDIAG- signal, and negates the DASP- signal when asserting the PDIAG- signal.
Max. 31 sec.
Max. 30 sec.
Max. 1 ms.
If the slave device is preset, DASP- is checked for up to
31 seconds.
DASP-
PDIAG-
BSY bit
X"00"
X'3F6' Reg.
X"0C"
or X"04"
Status Reg.
BSY bit
Slave device
Master device
Figure 6.3
Response to software reset
Содержание MPG3102AT
Страница 1: ...C141 E110 03EN MPG3xxxAT DISK DRIVES PRODUCT MANUAL ...
Страница 3: ...This page is intentionally left blank ...
Страница 15: ...This page is intentionally left blank ...
Страница 31: ...3 2 C141 E110 03EN Figure 3 1 Dimensions ...
Страница 47: ...This page is intentionally left blank ...
Страница 67: ...This page is intentionally left blank ...
Страница 201: ......