![Fujitsu MPG3102AT Скачать руководство пользователя страница 128](http://html.mh-extra.com/html/fujitsu/mpg3102at/mpg3102at_product-manual_121591128.webp)
C141-E110-03EN
5 - 61
*18
Total error count
It indicates that the total count of the error registered in the error log.
*19
Check sum
Twos complement of the lower byte, obtained by adding 511-byte data one by at a time from
the beginning.
Table 5.13 Self Test log data structure
Byte
Description
0 to 1
Data Structure Revision Number = 0x0001
1
st
Descriptor Entry
2
Self Test Number
3
Self Test Execution Status
4 to 5
Life time power on hours
6
Self Test Error No.
7 to 10
Error LBA
11 to 25
Vendor Specific bytes
26 to 49
2
nd
Descriptor Entry
!!!
!!!
482 to 505
21
st
Descriptor Entry
506 to 507
Vendor Specific
508
Self Test Index
509 to 510
Reserved
511
Checksum
•
Self Test Number
This byte shows executed Self Test Number.
•
Self Test Execution Status
Refer to explanation of Attribute Byte 16Bh.
•
Self Test Index
When it is “00h”, it means that Self Test has not been performed.
•
Check Sum
Twos complement of the lower byte, obtained by adding 511-byte data one by at a
time from the beginning.
Содержание MPG3102AT
Страница 1: ...C141 E110 03EN MPG3xxxAT DISK DRIVES PRODUCT MANUAL ...
Страница 3: ...This page is intentionally left blank ...
Страница 15: ...This page is intentionally left blank ...
Страница 31: ...3 2 C141 E110 03EN Figure 3 1 Dimensions ...
Страница 47: ...This page is intentionally left blank ...
Страница 67: ...This page is intentionally left blank ...
Страница 201: ......