4.3 SCSI Commands
C156-E224-01EN
4-15
Table 4.13 Block descriptor
Bit
Byte
7
6
5
4
3
2
1
0
0
Density Code (00h)
1-3
Number of Blocks
4
Reserved
5-7
Block Length
Table 4.14 shows the format of the Mode Page field.
Table 4.14 Mode page
Bit
Byte
7
6
5
4
3
2
1
0
0
PS
0
Page Code
1
Page Length (n-1)
2-n
Mode Parameters
(1) Read/write error recovery page
Table 4.15 Read/write error recovery page
Bit
Byte
7
6
5
4
3
2
1
0
0
PS (1)
0
Page Code (01h)
1
Page Length (0Ah)
2
AWRE
Reserved
Reserved
RC
Reserved
PER
Reserved
DCR
3
Read Retry Count
4-7
Reserved
8
Write Retry Count
9-11
00h
If the Automatic Write Reallocation Enabled (AWRE) bit is 0, no automatic
alternate block assignment is made by the WRITE (6), WRITE (10), or WRITE
AND VERIFY command. If the AWRE bit is 1, an automatic alternate block
assignment function is enabled.
If the Read Continuous (RC) bit is 0, an error is reported if an uncorrectable data
error is detected in the READ (6) or READ (10) command. If the RC bit is 1, the
command transfers the erroneous data and ends normally even if an uncorrectable
data error is detected.
If the Post Error (PER) bit is 0, the command reports GOOD status if an error is
corrected with the error recovery process. If the PER bit is 1, the command
reports CHECK CONDITION status if an error is corrected with the error recover
process. The Sense Key is then set to RECOVERED ERROR.
RECOVERED ERROR is reported when:
Содержание MCJ3230SS
Страница 1: ...C156 E224 01EN MCJ3230SS OPTICAL DISK DRIVE PRODUCT MANUAL ...
Страница 4: ...This page is intentionally left blank ...
Страница 19: ...C156 E224 01EN xv Figure 6 1 Revision label 6 4 Figure 6 2 Revision number indication 6 4 ...
Страница 22: ...This page is intentionally left blank ...
Страница 34: ...This page is intentionally left blank ...
Страница 46: ...Specifications 2 12 C156 E224 01EN Figure 2 3 Example of alternate processing ...
Страница 52: ...Installation Requirements 3 6 C156 E224 01EN Unit mm Figure 3 3 Dimensions without panel ...
Страница 59: ...3 4 Cable Connections C156 E224 01EN 3 13 PC board Figure 3 11 Shape of setting terminal ...
Страница 74: ...This page is intentionally left blank ...
Страница 124: ...Host Interface 4 50 C156 E224 01EN Figure 4 5 ARBITRATION phase ...
Страница 125: ...4 5 Timing Rule C156 E224 01EN 4 51 µ Figure 4 6 SELECTION phase Figure 4 7 RESELECTION phase ...
Страница 126: ...Host Interface 4 52 C156 E224 01EN Figure 4 8 Transfer in asynchronous mode ...
Страница 127: ...4 5 Timing Rule C156 E224 01EN 4 53 Figure 4 9 Transfer in FAST SCSI mode ...
Страница 128: ...Host Interface 4 54 C156 E224 01EN Figure 4 10 ATTENTION condition ...
Страница 150: ...This page is intentionally left blank ...
Страница 158: ...This page is intentionally left blank ...
Страница 160: ......
Страница 161: ......