![Fujitsu MBA3073RC SERIES Скачать руководство пользователя страница 312](http://html.mh-extra.com/html/fujitsu/mba3073rc-series/mba3073rc-series_technical-manual_121523312.webp)
Parameter Data Format
5.1.8 Notch Parameters (Page Code = 0C)
Table 5.10 MODE SELECT parameters: notch parameters
Bit
Byte
7 6 5 4 3 2 1 0
0 0
0
0
0
1
1
0
0
1
X'16' (Page Length)
2 ND
LPN
X'00'
(Reserved)
Default 0 0 0
0
0
0
0
0
Variable 0 1 0
0
0
0
0
0
3 X'00'
(Reserved)
4-5
Maximum number of notches
Default
X'001D'
Variable
X'0000'
6-7 Active
Notch
Default
X'0000'
Variable
X'FFFF'
8-11 Starting
Boundary
Default
X'00000000'
Variable
X'00000000'
12-15 Ending
Boundary
Default
X'xxxxxxxx'
Variable
X'00000000'
16-23 Page
Notch
Default
X'0000000000000008'
Variable
X'0000000000000000'
This page is used to report the top address and final address of each zone.
If the zone 1 of the notching zone is set in the "Active notch" field and
this parameter is issued, the starting and ending address of the specified zone can
be referred to by the MODE SENSE command.
Also, if Page 3 and Page 3F are specified by the MODE SENSE command, the
parameters below the zone specified in the notch page can be referred to.
•
Track/zone (Page 3, Byte 02, 03) (Note)
•
Sector count/track (Page 3, Bytes 10, 11)
•
Track Skew Factor (Page 3, Bytes 16, 17)
•
Cylinder Skew Factor (Page 3, Bytes 18, 19)
308
C141-C013
Содержание MBA3073RC SERIES
Страница 4: ...This page is intentionally left blank ...
Страница 106: ...SAS Interface 102 C141 C013 ...
Страница 138: ...This page is intentionally left blank ...
Страница 362: ...This page is intentionally left blank ...
Страница 422: ...This page is intentionally left blank ...
Страница 435: ...This page is intentionally left blank ...
Страница 437: ......
Страница 438: ......
Страница 439: ......