![Fujitsu MBA3073RC SERIES Скачать руководство пользователя страница 202](http://html.mh-extra.com/html/fujitsu/mba3073rc-series/mba3073rc-series_technical-manual_121523202.webp)
Command Specifications
198
C141-C013
The format of the Reservation descriptors is defined in Table 4.27.
Table 4.27 Format of reservation descriptors
Bit
Byte
7
6
5
4
3
2
1
0
0
(MSB)
Reservation Key
7
(LSB)
8
(MSB)
Scope-specific Address
11
(LSB)
12
X'00' (Reserved)
13
Scope
Type
14-15
X'00' (Reserved)
The Reservation Descriptor in the parameter data contains the information on
each reserve condition held in the logical unit. The Descriptor contains the
Reservation key of the INIT that holds the reserve conditions. It also contains the
"Type" and "Scope" reserve condition values specified by the PERSISTENT
RESERVE OUT command.
The "Reservation key" field indicates the Reservation key registered with its
reserve condition. If each INIT uses a key specific to itself, the application needs
to know the association of the INIT that holds a reserve condition with a
Reservation key.
If the "Scope" value is element reserve, the "Scope-specific Address" field
indicates the element address (with the high byte filled with 0's). If the Scope
value is logical unit reserve, the "Scope-specific Address" field is set to zero.
Remarks: Element reserve is not supported.
~
~
~
~
~
~
Содержание MBA3073RC SERIES
Страница 4: ...This page is intentionally left blank ...
Страница 106: ...SAS Interface 102 C141 C013 ...
Страница 138: ...This page is intentionally left blank ...
Страница 362: ...This page is intentionally left blank ...
Страница 422: ...This page is intentionally left blank ...
Страница 435: ...This page is intentionally left blank ...
Страница 437: ......
Страница 438: ......
Страница 439: ......