515
CHAPTER 23 CAN CONTROLLER
Figure 23.13-1 Examples of Operation of Multi-level Message Buffer
Note:
Four messages are received with the same acceptance filter set in message buffers 13, 14 and 15.
Initialization
10 10 10
. . .
AMSR
AMS15, AMS14, AMS13
0000 1111 111
AMS0
AM28 to AM18
. . .
RCR
ROVRR
RC15, RC14, RC13
0
0
0
0
0
0
. . .
. . .
ROVR15, ROVR14, ROVR13
Message buffer 13
Message buffer 14
Message buffer 15
0101 0000 000
0101 0000 000
0101 0000 000
0
0
0
. . .
. . .
. . .
ID28 to ID18
IDE
Mask
RCR
ROVRR
0
0
0
0
Message receiving
Message buffer 13
Message buffer 14
Message buffer 15
ID28 to ID18
IDE
0101 1111 000
0101 1111 000
0101 0000 000
0101 0000 000
0
0
0
0
1
0
Select AMR0.
Message receiving
"The received message is stored in message buffer 13.
RCR
ROVRR
0
0
1
0
Message receiving
Message buffer 13
Message buffer 14
Message buffer 15
0101 1111 001
0101 1111 000
0101 1111 001
0101 0000 000
0
0
0
0
1
0
Message receiving
"The received message is stored in message buffer 14.
Message receiving
"The received message is stored in message buffer 15.
RCR
ROVRR
1
0
1
0
Message receiving
Message buffer 13
Message buffer 14
Message buffer 15
0101 1111 010
0101 1111 000
0101 1111 001
0101 1111 010
0
0
0
0
1
0
Message receiving "An overrun occurs (ROVR13 = 1) and the received message is stored in message buffer 13.
RCR
ROVRR
1
0
1
0
Message receiving
Message buffer 13
Message buffer 14
Message buffer 15
0101 1111 011
0101 1111 011
0101 1111 001
0101 1111 010
0
0
0
0
1
1
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
. . .
Содержание MB90390 Series
Страница 2: ......
Страница 4: ......
Страница 17: ...xiii APPENDIX D List of Interrupt Vectors 690 INDEX 695 ...
Страница 18: ...xiv ...
Страница 132: ...104 CHAPTER 5 CLOCKS ...
Страница 152: ...124 CHAPTER 6 CLOCK MODULATOR ...
Страница 210: ...182 CHAPTER 11 TIME BASE TIMER ...
Страница 218: ...190 CHAPTER 12 WATCHDOG TIMER ...
Страница 264: ...236 CHAPTER 14 16 BIT RELOAD TIMER WITH EVENT COUNT FUNCTION ...
Страница 274: ...246 CHAPTER 15 WATCH TIMER ...
Страница 306: ...278 CHAPTER 17 DTP EXTERNAL INTERRUPTS ...
Страница 338: ...310 CHAPTER 18 8 10 BIT A D CONVERTER ...
Страница 364: ...336 CHAPTER 19 UART0 UART1 ...
Страница 398: ...370 CHAPTER 20 UART2 UART3 Figure 20 5 2 ORE Set Timing Receive data RDRF ORE ...
Страница 432: ...404 CHAPTER 20 UART2 UART3 ...
Страница 482: ...454 CHAPTER 22 SERIAL I O ...
Страница 560: ...532 CHAPTER 24 STEPPING MOTOR CONTROLLER ...
Страница 582: ...554 CHAPTER 27 ROM MIRRORING MODULE ...
Страница 632: ...604 CHAPTER 29 EXAMPLES OF SERIAL PROGRAMMING CONNECTION ...
Страница 722: ...694 APPENDIX ...
Страница 723: ...695 INDEX The index follows on the next page This is listed in alphabetic order ...
Страница 740: ......