C141-E166
3-15
•
Automatic alternate block allocation at write operation
If AWRE flag in the MODE SELECT parameter permits the automatic alternate block allocation,
the IDD executes the automatic alternate processing during WRITE command processing as
described below:
1) Commands to be applied
-
WRITE
-
WRITE EXTEND
-
WRITE at executing WRITE AND VERIFY
2) Application requirements
When any of the above commands is issued to LBA registered in the uncorrectable error log of
the READ command (LBA log of uncorrectable error while the READ command is executed),
the AWRE processing is applied.
3) AWRE processing
The following processings are performed when the LBA matches the one in the uncorrectable
error log:
a)
Primary media check
-
Creates an uncorrectable error pattern (invalid LBA pattern) in the position of the
error LBA, repeats the primary media check up to three times. If the error still occurs
after the check repeated three times, it is judged to be defective. Then, it performs the
alternate processing.
b)
Alternate processing
-
Alternate media check
Writes the data that causes an unrecoverable error into the alternate block, and
performs the media check.
(If the alternate block is a defective sector, the block is registered to the G list, another
alternate block is allocated.)
c)
SA and defect map update processing (on alternate side)
When an error occurs in the alternate processing, this WRITE command terminates with error.
When the alternate processing normally terminates, the WRITE command is executed.
Depending on the alternate processing result, one of the following sense codes is returned:
Alternate processing is succeeded: 01-OC-01
Alternate medium is defective:
03-OC-01
Fatal error (SA write retry out):
03-OC-02
Содержание MAP3147NC - Enterprise - Hard Drive
Страница 1: ...C141 E166 01EN MAP3147NC NP MAP3735NC NP MAP3367NC NP DISK DRIVES PRODUCT MAINTENANCE MANUAL ...
Страница 10: ...This page is intentionally left blank ...
Страница 14: ...This page is intentionally left blank ...
Страница 18: ...This page is intentionally left blank ...
Страница 36: ...This page is intentionally left blank ...
Страница 66: ...4 14 C141 E166 Figure 4 17 External operator panel connector CN2 ...
Страница 88: ...5 14 C141 E166 Motor starts when power is turned on Figure 5 4 Checking the SCSI connection A 60 ...
Страница 122: ...This page is intentionally left blank ...
Страница 126: ...This page is intentionally left blank ...
Страница 128: ...This page is intentionally left blank ...
Страница 130: ...This page is intentionally left blank ...
Страница 131: ......
Страница 132: ......