5.5 Checking Operation after Installation and Preparing the IDD for Use
C141-E133-02EN
5-15
(3)
Caching parameters
The following parameters are used to optimize IDD Read-Ahead caching operations under the system
environments. Refer to Chapter 2 of Fibre Channel Interface Specifications for further details.
Parameter
Default value
• IC:
Initiator control
0 (Drive-specific
control (page
cache))
• RCD:
Disabling Read-Ahead caching operations
0 (enabled)
• WCE:
Write Cache Enable
1 (enabled)
• MS:
Specifying the multipliers of "minimum
prefetch" and "maximum prefetch" parameters
0 (Specifying
absolute value)
• DISC:
Prefetch operation after track switching during
prefetching
0 (inhibit)
• Number of blocks for which prefetch is suppressed
X'FFFF'
• Minimum prefetch
X'0000'
• Maximum prefetch
X' XXXX'
(1 cache segment)
• Number of blocks with maximum prefetch restrictions
X'FFFF'
• Number of segments
X'10'
Notes:
1.
When Read-Ahead caching operations are disabled by the caching parameter, these
parameter settings have no meaning except write cache feature.
2.
Determine the parameters in consideration of how the system accesses the disk. When the
access form is not determined uniquely because of the processing method, the parameters
can be re-set actively.
3.
For sequential access, the effective access rate can be increased by enabling Read-Ahead
caching operations and Write Cache feature.
(4)
Control mode parameters
The following parameters are used to control the tagged queuing and error logging.
Содержание MAN3367FC - Enterprise 36.7 GB Hard Drive
Страница 1: ...C141 E133 02EN MAN3735FC SERIES MAN3367FC SERIES DISK DRIVES PRODUCT MAINTENANCE MANUAL ...
Страница 4: ......
Страница 6: ...This page is intentionally left blank ...
Страница 14: ...This page is intentionally left blank ...
Страница 16: ...This page is intentionally left blank ...
Страница 21: ...Contents C141 E133 02EN xv Glossary GL 1 Abbreviations AB 1 Index IN 1 ...
Страница 24: ...This page is intentionally left blank ...
Страница 40: ...This page is intentionally left blank ...
Страница 56: ...This page is intentionally left blank ...
Страница 66: ...Installation Requirements 4 10 C141 E133 02EN Figure 4 10 SCA2 type connector ...
Страница 110: ...Principle of Operation 8 8 C141 E133 02EN Figure 8 3 Block diagram of read write circuit ...
Страница 116: ...This page is intentionally left blank ...
Страница 132: ...This page is intentionally left blank ...
Страница 136: ...This page is intentionally left blank ...
Страница 144: ...This page is intentionally left blank ...
Страница 146: ...This page is intentionally left blank ...
Страница 147: ......
Страница 148: ......